{"product_id":"pfeiffer-hipace-2300-uc-turbomolecular-pump-refurbished","title":"Pfeiffer HiPace 2300 Turbomolecular Pump with TC 1200","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Pfeiffer HiPace 2300 represents the pinnacle of turbomolecular pump technology, delivering exceptional performance for demanding high-vacuum applications. This powerful turbopump combines impressive pumping speeds with an integrated TC 1200 drive electronics system, making it ideal for semiconductor manufacturing, research facilities, and industrial coating processes. With its hybrid bearing design and water cooling system, the HiPace 2300 ensures reliable operation and maintains optimal temperature control even under challenging conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"330\"\u003e \u003ccol width=\"294\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePumping Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eN2: 1,900 l\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAr: 1,800 l\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHe: 2,000 l\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eH2: 1,850 l\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUltimate Pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u0026lt; 1 × 10⁻⁷ hPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCompression Ratio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eN2: \u0026gt; 1 × 10⁸\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAr: \u0026gt; 1 × 10⁸\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHe: 3 × 10⁵\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eH2: 2 × 10⁴\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRotation Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e31,500 rpm ± 2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRun-up Time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCooling Method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWater cooling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCooling Water Flow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e100 l\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCooling Water Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15-35°C (59-95°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e200-240 VAC, 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMax 1,350 VA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eConnection Flanges\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInlet: DN 250 ISO-F\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOutlet: DN 40 ISO-KF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBearing Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHybrid\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIP54\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e≤ 50 dB(A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e36.8 kg (81.1 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMounting Orientation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0° to 90° (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePermissible Magnetic Field\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMax 7 mT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe HiPace 2300 features variable speed control from 50-100% and integrated sealing gas capability for process protection. Its sophisticated rotor design delivers excellent compression ratios and high gas throughput capacity, while the hybrid bearing system combines maintenance-free permanent magnetic bearings on the high vacuum side with robust ceramic ball bearings on the fore-vacuum side.\u003c\/span\u003e\u003c\/p\u003e","brand":"Pfeiffer","offers":[{"title":"PM P06 394A - IU - Ion Implantation and Upside Down","offer_id":45728915914941,"sku":"Pfeiffer PM 006 336 Refurbished-1","price":21985.0,"currency_code":"USD","in_stock":true},{"title":"PM P04 359B - UC - Upside Down and Corrosion Resistance","offer_id":45728915947709,"sku":"Pfeiffer PM 006 336 Refurbished-2","price":21985.0,"currency_code":"USD","in_stock":true},{"title":"PM P04 144 A - U - Upside Down","offer_id":45728915980477,"sku":"Pfeiffer PM 006 336 Refurbished-3","price":21985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/Pfeiffer_HiPace_2300_UC_Turbomolecular_Pump_32c22176-ebae-49ee-87b0-9d2290a879e5.png?v=1735941779","url":"https:\/\/labvac.com\/products\/pfeiffer-hipace-2300-uc-turbomolecular-pump-refurbished","provider":"Labvac","version":"1.0","type":"link"}