{"product_id":"edwards-scu-800-turbo-molecular-pump-control-unit","title":"Edwards SCU-800 Turbo Molecular Pump Control Unit","description":"\u003cp id=\"p-rc_71ff216d8443e74e-43\"\u003e\u003cspan class=\"citation-81\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-81\"\u003eEdwards SCU-800\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-81\"\u003e (Part Number: \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-81\"\u003eYT49-Z3-Z20\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-81 citation-end-81\"\u003e) is a fully digital, universal control unit designed for magnetically suspended turbomolecular pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-80 citation-end-80\"\u003eBuilt to support medium-capacity STP series turbo pumps, the SCU-800 incorporates Auto Vibration Reduction (AVR) and Auto Balancing System (ABS) technologies to minimize rotational vibration and deliver consistent, ultra-high vacuum performance.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-44\"\u003e\u003cspan class=\"citation-79 citation-end-79\"\u003eThis controller features standard serial communication interfaces (RS-232\/RS-485), advanced predictive maintenance alerts, and compliance with international semiconductor safety standards including CE, UL, and SEMI S2.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Digital Magnetic Bearing Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 200–240 VAC (±10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \/ 60 Hz (±2 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 850 VA (w\/o TMS) \/ Max 1200 VA (w\/ TMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMotor Drive System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMain Breaker Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLeakage Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDisplay Panel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated LCD Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RS-232 \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132.5 mm × 209.7 mm × 380.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~8.5 kg (18.7–20 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSafety Compliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, SEMI S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-45\"\u003e\u003cspan class=\"citation-78 citation-end-78\"\u003eThe SCU-800 serves as a universal controller for middle-sized Edwards and Seiko Seiki Maglev turbomolecular pumps:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-46\"\u003e\u003cb\u003e\u003cspan class=\"citation-77 citation-end-77\"\u003eSTP-603 \/ STP-1003 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-47\"\u003e\u003cb\u003e\u003cspan class=\"citation-76 citation-end-76\"\u003eSTP-H301 \/ STP-H451 \/ STP-H803 \/ STP-H1303 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-48\"\u003e\u003cb\u003e\u003cspan class=\"citation-75 citation-end-75\"\u003eSTP-A803C \/ STP-A1303 \/ STP-A1603 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-49\"\u003e\u003cb\u003eUniversal Compatibility:\u003c\/b\u003e \u003cspan class=\"citation-74 citation-end-74\"\u003eA single SCU-800 controller supports multiple middle-sized pump models, simplifying backup equipment inventories in multi-pump laboratory setups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Vibration Suppression:\u003c\/b\u003e Embedded Auto Vibration Reduction (AVR) dynamically balances the magnetic bearing suspension during acceleration and steady-state operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-50\"\u003e\u003cb\u003ePredictive Diagnostics:\u003c\/b\u003e \u003cspan class=\"citation-73 citation-end-73\"\u003eAdvanced pre-maintenance functions track run hours, rotor stability, and thermal loads to give notice prior to scheduled maintenance cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-51\"\u003e\u003cb\u003eDual Serial Communication:\u003c\/b\u003e \u003cspan class=\"citation-72 citation-end-72\"\u003eIntegrated RS-232 and RS-485 ports enable concurrent connection to local PC interfaces and automated fab-wide monitoring systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47944473084093,"sku":null,"price":5495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-800_1.jpg?v=1785864810","url":"https:\/\/labvac.com\/products\/edwards-scu-800-turbo-molecular-pump-control-unit","provider":"Labvac","version":"1.0","type":"link"}