{"title":"Controllers","description":"\u003cp\u003eMotor controllers for turbo molecular pumps\u003c\/p\u003e","products":[{"product_id":"edwards-scu1600-turbopump-control-unit-refurbished","title":"Edwards SCU 1600 Turbopump Control Unit","description":"\u003cp class=\"MsoNormal\"\u003eThe Edwards SCU 1600 is a state-of-the-art control unit designed to optimize the performance of large-sized turbomolecular pumps. With its advanced features and intuitive interface, the SCU 1600 ensures reliable and efficient operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eVibration Reduction System (VRS):\u003c\/b\u003e Significantly reduces vibration levels, leading to quieter operation and extended pump life.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003ePre-Maintenance Call Functions:\u003c\/b\u003e Proactively alerts users to potential maintenance needs, minimizing downtime.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eEnhanced Communication:\u003c\/b\u003e Enables remote monitoring and control, providing flexibility and convenience.  \u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eCompatibility:\u003c\/b\u003e Compatible with a wide range of Edwards turbomolecular pumps, ensuring seamless integration.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eRobust Design:\u003c\/b\u003e Built to withstand demanding industrial environments and provide long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":44748626493629,"sku":"Edwards YT49-Z0-Z00 Refurbished","price":7985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/Edwards_SCU_1600_Turbopump_Control_Unit_ebe417dd-7b86-4df8-9f8e-b8388212ad29.jpg?v=1735941743"},{"product_id":"adixen-mag-power-controller","title":"Adixen MAG Power Controller","description":"\u003cp\u003eThis \u003cb\u003eAdixen MAG Power Controller\u003c\/b\u003e is the ideal solution for operating and monitoring your magnetically levitated turbomolecular pumps. Designed for high-performance vacuum systems, this controller provides reliable and precise control for a range of demanding applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDigital External Drive Electronics:\u003c\/b\u003e Offers advanced control and monitoring capabilities for your vacuum system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Design:\u003c\/b\u003e At a 1\/2 of 19\" rack size, it saves valuable space in your equipment setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-7\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-7\"\u003eFull Pump Interoperability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003e Designed to be fully interchangeable with various Adixen ATH-M and ATP-M series pumps, ensuring flexibility and ease of integration.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003cbutton class=\"button ng-star-inserted\" data-hveid=\"0\" data-ved=\"0CAAQvoAQahgKEwjDpPzdms-PAxUAAAAAHQAAAAAQlAI\"\u003e\u003c\/button\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAdvanced Safety Features:\u003c\/b\u003e The controller is engineered with a battery-free system, where in case of a power failure, the pump's rotor generates power to maintain levitation, ensuring a safe and controlled shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComprehensive Pump Monitoring:\u003c\/b\u003e The unit provides a digital display for operating and troubleshooting parameters, including speed, power consumption, and temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button\"\u003e\n\u003cdiv class=\"table-content not-end-of-paragraph\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjDpPzdms-PAxUAAAAAHQAAAAAQlQI\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAdixen (Pfeiffer Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMAG Power Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200-240 V, 50\/60 Hz, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Power Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kW (with heater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions (L x W x H)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e450 mm x 219 mm x 132.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg (19 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSupported Pumps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAdixen ATH-M and ATP-M series (excluding ATH 500 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Alcatel","offers":[{"title":"Default Title","offer_id":45400170135741,"sku":null,"price":8985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/frontPanelblurred.jpg?v=1757543973"},{"product_id":"edwards-scu-1601-controller","title":"Edwards SCU 1601 Controller","description":"\u003cp\u003e\u003cspan class=\"citation-19\"\u003eThis \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-19\"\u003eEdwards SCU 1601 Controller\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-19 citation-end-19\"\u003e is a powerful and reliable digital control unit designed to operate Edwards STP series turbomolecular pumps.\u003csup data-turn-source-index=\"1\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e It's an essential component for maintaining precise vacuum levels in a wide array of scientific and industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-18\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-18\"\u003eDigital Control System:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-18 citation-end-18\"\u003e Features a fully digital magnetic bearing control system for precise and stable pump operation.\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWide Pump Compatibility:\u003c\/b\u003e Specifically designed to be compatible with Edwards STP turbo pumps ranging from 2000 l\/s to 4500 l\/s (note: research indicates SCU-1600 is for this range, the SCU-1601 likely shares this compatibility or is an evolution).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-17\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-17\"\u003eEnhanced Communication:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-17 citation-end-17\"\u003e Offers serial communication capabilities (RS232\/RS485) for remote control, monitoring, and data logging.\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-16\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-16\"\u003eUser-Friendly Interface:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-16 citation-end-16\"\u003e Equipped with an LCD panel display for clear operational status and diagnostic information.\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-15\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-15\"\u003eAdvanced Diagnostics:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-15 citation-end-15\"\u003e Includes pre-maintenance functions, rotor imbalance monitoring, and self-diagnosis capabilities for proactive maintenance and reduced downtime.\u003csup data-turn-source-index=\"5\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-14\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-14\"\u003eCompact Design:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14 citation-end-14\"\u003e Often features a half-rack controller format, making it space-efficient in laboratory or industrial setups.\u003csup data-turn-source-index=\"6\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button\"\u003e\n\u003cdiv data-ved=\"0CAAQ3ecQahgKEwjDpPzdms-PAxUAAAAAHQAAAAAQrwI\" data-hveid=\"0\" class=\"table-content not-end-of-paragraph\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards Vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSCU 1601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200 - 240 ±10% V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 ±2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Consumption (without TMS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 1600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Consumption (with TMS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 2100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMotor Drive System\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase DC brushless motor drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAllowable Ambient Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40°C (32 to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions (Approx.)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e132.5 mm (H) x 209.7 mm (W) x 498.5 mm (L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight (Approx.)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e11 - 12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCommunication Interface\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232\/RS485 (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSupported Pump Series (Typical)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards STP-A2203, STP-A2503, STP-A3003, STP-A2803, STP-A3503, STP-F2203, STP-XH2603, STP-XH3203, STP-XA2703, STP-XA3203, STP-XA4503, STP-XW3503 (and similar models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":45400210768061,"sku":null,"price":9850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/FrontPanelBlurred_74fccaaa-b332-4bfd-b09b-1ad73d0ac7b4.jpg?v=1757544671"},{"product_id":"edwards-scu-350ha-controller-for-turbomolecular-pumps","title":"Edwards SCU 350HA Controller for Turbomolecular Pumps","description":"\u003cp\u003eThis \u003cb\u003eEdwards SCU 350HA controller\u003c\/b\u003e is a highly reliable digital unit designed to operate Edwards turbomolecular pumps, particularly those in the STP-301\/451 and STPL-301\/451 series. It offers precise control and monitoring capabilities, essential for maintaining optimal vacuum performance in research, development, and industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDigital Magnetic Bearing Control:\u003c\/b\u003e\u003cspan class=\"citation-47 citation-end-47\"\u003e Utilizes advanced digital control for stable and efficient operation of magnetically levitated turbopumps.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUniversal Voltage Input:\u003c\/b\u003e\u003cspan class=\"citation-46 citation-end-46\"\u003e Features a universal voltage function, allowing operation with supply voltages from 100-240 VAC without manual switching, simplifying installation and inventory.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eImproved Vibration Property:\u003c\/b\u003e Incorporates enhanced vibration reduction systems for smoother operation and reduced mechanical stress on connected equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEnergy Saving:\u003c\/b\u003e\u003cspan class=\"citation-45 citation-end-45\"\u003e Lower input power requirements contribute to reduced overall energy consumption.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact and Space-Saving:\u003c\/b\u003e\u003cspan class=\"citation-44 citation-end-44\"\u003e The controller's compact design, often a half-rack unit, makes it ideal for systems with limited space.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-43\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-43\"\u003eEnhanced Noise Immunity:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-43 citation-end-43\"\u003e Designed with improved noise immunity for reliable performance in electrically noisy environments.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-42\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-42\"\u003eComprehensive Diagnostics:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-42 citation-end-42\"\u003e Provides clear diagnostic information via an LCD panel for easy monitoring and troubleshooting.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSerial Communication:\u003c\/b\u003e Equipped with RS232\/RS485 communication for remote control, monitoring, and data logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button\"\u003e\n\u003cdiv class=\"table-content not-end-of-paragraph\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjDpPzdms-PAxUAAAAAHQAAAAAQ5QI\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards Vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSCU 350HA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e100 - 120 VAC \/ 200 - 240 VAC (Universal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 ±2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Consumption (Start-up)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 350 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Consumption (Continuous)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 150 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMain Breaker Rated Current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMotor Drive System\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAllowable Ambient Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePanel Display\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCommunication Interface\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSTP-301, STP-451, STPL-301, STPL-451 (and similar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":45400264900797,"sku":null,"price":7985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/FrontPanelBlurred_91259ffc-f2e0-4206-bb33-f7e2e1644c6b.jpg?v=1757545949"},{"product_id":"shimadzu-ei-d3403-2203-controller","title":"Shimadzu EI-D3403 (2203) Controller","description":"\u003cp data-path-to-node=\"5\"\u003eThe \u003cb data-path-to-node=\"5\" data-index-in-node=\"4\"\u003eShimadzu EI-D3403M (2203)\u003c\/b\u003e is an industrial, rack-mounted power supply and control unit engineered specifically for large-scale, magnetically levitated turbomolecular vacuum pumps. Designed to manage high-rotational velocities safely, this controller dynamically governs the magnetic bearing system and motor excitation parameters for \u003cb data-path-to-node=\"5\" data-index-in-node=\"338\"\u003eShimadzu TMP-2203\u003c\/b\u003e and \u003cb data-path-to-node=\"5\" data-index-in-node=\"360\"\u003eTMP-3403\u003c\/b\u003e series pumps. It provides precise rotational speed stabilization, real-time diagnostic output, and built-in protection against sudden venting or kinetic abnormalities.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eTechnical Specifications Matrix\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahcKEwj84OaL-ciUAxUAAAAAHQAAAAAQIA\"\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,0,0\"\u003eFeature \/ Attribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,1,0\"\u003eFactory Standard Specification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eShimadzu Corporation (Made in Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-path-to-node=\"8,2,0,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eEI-D3403M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-path-to-node=\"8,3,0,0\" data-index-in-node=\"0\"\u003eConfiguration Profile\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e(2203) \/ Typically paired with TMP-2203 \u0026amp; TMP-3403\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-path-to-node=\"8,4,0,0\" data-index-in-node=\"0\"\u003eCompatible Pumps\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003eTMP-2203M, TMP-2203LMC, TMP-3403LM, TMP-3403LMC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-path-to-node=\"8,5,0,0\" data-index-in-node=\"0\"\u003eBearing Support Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003eActive 5-Axis Magnetic Levitated Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003e\u003cb data-path-to-node=\"8,6,0,0\" data-index-in-node=\"0\"\u003eInput Power Requirements\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003eAC \u003cspan class=\"math-inline\" data-math=\"200\\text{V} - 240\\text{V} \\pm 10\\%\" data-index-in-node=\"3\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e200\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e−\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e240\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e±\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e, Single Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003e\u003cb data-path-to-node=\"8,7,0,0\" data-index-in-node=\"0\"\u003eRecommended Breaker\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e15A Rated Dedicated Service Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003e\u003cb data-path-to-node=\"8,8,0,0\" data-index-in-node=\"0\"\u003eProtective Grounding\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eDedicated PE (Protective Earth) Terminal Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003e\u003cb data-path-to-node=\"8,9,0,0\" data-index-in-node=\"0\"\u003ePhysical Form Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003eStandard 19-inch Rack Mount Ready\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003e\u003cb data-path-to-node=\"8,10,0,0\" data-index-in-node=\"0\"\u003eApproximate Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e~25 lbs (11.3 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"10\"\u003e\u003c\/h2\u003e\n\u003ch2 data-path-to-node=\"10\"\u003eKey Features \u0026amp; Operational Highlights\u003c\/h2\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eActive Magnetic Levitation Management:\u003c\/b\u003e Continuously monitors and adjusts the active 5-axis magnetic bearings to maintain flawless rotor equilibrium at high operational RPMs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVariable Speed Capability:\u003c\/b\u003e Supports precise speed control adjustments, allowing optimization of backing pressure performance and process gas compression ratios (\u003cspan class=\"math-inline\" data-math=\"1 \\times 10^9\" data-index-in-node=\"161\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e9\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e for \u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"179\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eIndustrial Communication \u0026amp; Safety I\/O:\u003c\/b\u003e Features rear-panel remote interfaces designed for seamless tool integration (compatible with Tokyo Electron \/ TEL platforms under specific sub-part architectures like 2L80-000684-V1).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eRapid Shutdown Torque Mitigation:\u003c\/b\u003e Built-in deceleration safety protocols designed to safely handle sudden torque variations or emergency vacuum breaches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Shimadzu","offers":[{"title":"Default Title","offer_id":46811186135229,"sku":null,"price":2499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EI-D3403_Front1.jpg?v=1776812085"},{"product_id":"shimadzu-tmp-2203lmc-bundle","title":"Shimadzu TMP 2203LMC Bundle","description":"\u003cp data-path-to-node=\"4\"\u003eThis high-capacity, clean-vacuum bundle is a comprehensive engineering solution designed for demanding industrial, semiconductor processing, and advanced R\u0026amp;D environments. The system pairs the industry-standard \u003cb data-path-to-node=\"4\" data-index-in-node=\"211\"\u003eShimadzu TMP-2203LMC\u003c\/b\u003e corrosive-resistant, magnetically levitated turbomolecular pump with its matching \u003cb data-path-to-node=\"4\" data-index-in-node=\"314\"\u003eEI-D3403M\u003c\/b\u003e variable-speed drive controller via a premium, heavy-duty 3-meter umbilical interconnect cable. This complete bundle provides a turn-key vacuum solution completely free of hydrocarbon contamination, featuring ultra-low vibration profiles and dynamic speed control logic.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"6\"\u003e1. System Component Breakdown \u0026amp; Specifications\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eComponent A: Shimadzu TMP-2203LMC Turbomolecular Vacuum Pump\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\" id=\"p-rc_9469951dfb34f2d1-59\"\u003eThe core of the system is a wide-range, high-throughput chemical type (\"C\" designation) turbomolecular pump equipped with fully active magnetic levitation bearings and water cooling. \u003cspan class=\"citation-128 citation-end-128\"\u003eIt is designed to reliably handle corrosive process gases.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\" id=\"p-rc_9469951dfb34f2d1-60\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePumping Speed (\u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e 2,050 L\/s (with protective net) \/ 2,140 L\/s (without net)\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\" id=\"p-rc_9469951dfb34f2d1-61\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePumping Speed (Light Gases):\u003c\/b\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e He: 2,000 L\/s | \u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"H_2\" data-index-in-node=\"45\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eH\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003e: 1,350 L\/s\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\" id=\"p-rc_9469951dfb34f2d1-62\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003eCompression Ratio (\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"19\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-123\"\u003e):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-123 citation-end-123\"\u003e \u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"1.4 \\times 10^8\" data-index-in-node=\"25\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1.4\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\" id=\"p-rc_9469951dfb34f2d1-63\"\u003e\u003cspan class=\"citation-122\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-122\"\u003eUltimate Pressure:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-122 citation-end-122\"\u003e \u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"10^{-7}\\text{ Pa}\" data-index-in-node=\"19\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−7\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-121 citation-end-121\"\u003e order (using standard elastomeric O-rings) \/ \u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"10^{-8}\\text{ Pa}\" data-index-in-node=\"82\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-120 citation-end-120\"\u003e order (baking with metal gaskets)\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\" id=\"p-rc_9469951dfb34f2d1-64\"\u003e\u003cspan class=\"citation-119\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-119\"\u003eInlet Flange Interface:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-119 citation-end-119\"\u003e ISO250F\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\" id=\"p-rc_9469951dfb34f2d1-65\"\u003e\u003cspan class=\"citation-118\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-118\"\u003eExhaust\/Foreline Flange:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-118 citation-end-118\"\u003e KF40\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eMax Allowable Argon Gas Flow:\u003c\/b\u003e 2,000 mL\/min (SCCM) continuous processing capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\" id=\"p-rc_9469951dfb34f2d1-66\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eRated Rotational Speed:\u003c\/b\u003e\u003cspan class=\"citation-117 citation-end-117\"\u003e 24,600 RPM (Full operational velocity reached within 11 minutes)\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\" id=\"p-rc_9469951dfb34f2d1-67\"\u003e\u003cspan class=\"citation-116\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-116\"\u003eCooling Parameters:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-116 citation-end-116\"\u003e Water cooled (Requires 1 to 3 L\/min flow rate at 0.2 to 0.5 MPa)\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbdi class=\"source-title\"\u003e\u003c\/bdi\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\" id=\"p-rc_9469951dfb34f2d1-68\"\u003e\u003cspan class=\"citation-115\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-115\"\u003ePhysical Mass:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-115 citation-end-115\"\u003e 121 lbs (59 kg)\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eComponent B: Shimadzu EI-D3403M (2203) Digital Drive Controller\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe micro-processor control deck manages power transformation, 5-axis magnetic position sensing loops, and variable frequency motor drive excitation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eForm Factor:\u003c\/b\u003e Standard 19-inch rack-mount chassis (approx. 25 lbs \/ 11.3 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eInput Mains Power:\u003c\/b\u003e AC \u003cspan class=\"math-inline\" data-math=\"200\\text{V} - 240\\text{V} \\pm 10\\%\" data-index-in-node=\"22\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e200\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e−\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e240\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e±\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e, Single-Phase, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eBearing Control Circuitry:\u003c\/b\u003e Active 5-Axis Magnetic Levitation feedback monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\" id=\"p-rc_9469951dfb34f2d1-69\"\u003e\u003cspan class=\"citation-114\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-114\"\u003eOperational Control Logic:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-114 citation-end-114\"\u003e Variable speed adjustments programmable between 25% and 100% of rated speed (adjustable in 0.1% increments for precise system pressure tuning)\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\" id=\"p-rc_9469951dfb34f2d1-70\"\u003e\u003cspan class=\"citation-113\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-113\"\u003eI\/O Communications:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-113 citation-end-113\"\u003e Multi-pin industrial remote contact blocks (Start\/Stop\/Reset input states; Normal\/Acceleration\/Brake\/Alarm status relays) alongside RS-232C serial interfacing\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eComponent C: Heavy-Duty 5-Meter Umbilical Interconnect Cable\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eThe high-flex unified bridge linking the controller chassis back-plane directly to the pump base.\u003c\/p\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eLength Geometry:\u003c\/b\u003e 3 Meters (~9.8 feet) optimal sub-fab or equipment rack drop length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eShielding Matrix:\u003c\/b\u003e Dual-layer defense containing independent foil wraps around sensitive low-voltage sensor pairs plus an overall heavy tinned copper braid to completely isolate motor harmonics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCoupling Enclosure:\u003c\/b\u003e Machined high-density circular military-spec connectors with solid threaded locking collars and integrated strain relief sleeves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"17\"\u003e2. Integrated System Performance Profile Matrix\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwj84OaL-ciUAxUAAAAAHQAAAAAQkAE\"\u003e\n\u003ctable data-path-to-node=\"18\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"18,0,0,0\"\u003eSystem Performance Attribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"18,0,1,0\"\u003eSpecification Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,1,0,0\"\u003e\u003cb data-path-to-node=\"18,1,0,0\" data-index-in-node=\"0\"\u003eCombined System Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,1,1,0\"\u003eComplete 5-Axis Mag-Lev High-Vacuum Loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,2,0,0\"\u003e\u003cb data-path-to-node=\"18,2,0,0\" data-index-in-node=\"0\"\u003eTotal System Mass\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,2,1,0\"\u003e~146 lbs (66.3 kg) combined hardware weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,3,0,0\"\u003e\u003cb data-path-to-node=\"18,3,0,0\" data-index-in-node=\"0\"\u003ePumping Mechanism\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,3,1,0\"\u003eOil-Free, Contactless Levitation (Zero Wear \/ Contamination)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,4,0,0\"\u003e\u003cb data-path-to-node=\"18,4,0,0\" data-index-in-node=\"0\"\u003eMounting Orientation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,4,1,0\"\u003eArbitrary (Can be installed in any physical axis orientation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,5,0,0\"\u003e\u003cb data-path-to-node=\"18,5,0,0\" data-index-in-node=\"0\"\u003eVibration Signature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,5,1,0\"\u003e0.01 µm or less (0-to-peak) due to magnetic balancing loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,6,0,0\"\u003e\u003cb data-path-to-node=\"18,6,0,0\" data-index-in-node=\"0\"\u003ePurge Gas Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,6,1,0\"\u003eIntegrated port for dry \u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"24\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e protection gas feed (20 to 30 mL\/min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,7,0,0\"\u003e\u003cb data-path-to-node=\"18,7,0,0\" data-index-in-node=\"0\"\u003eRecommended Backing Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"18,7,1,0\"\u003e800 L\/min (\u003cspan class=\"math-inline\" data-math=\"48\\text{ m}^3\/\\text{hr}\" data-index-in-node=\"11\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e48\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord text\"\u003e m\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e3\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\/\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003ehr\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) or greater capacity backing speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"20\"\u003e3. Critical Sourcing, Pairing, \u0026amp; Safety Protocols\u003c\/h2\u003e\n\u003cblockquote data-path-to-node=\"21\"\u003e\n\u003ch3 data-path-to-node=\"21,0\"\u003e⚠️ Critical Installation \u0026amp; Operational Mandates\u003c\/h3\u003e\n\u003col start=\"1\" data-path-to-node=\"21,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0,0\" id=\"p-rc_9469951dfb34f2d1-71\"\u003e\u003cspan class=\"citation-112\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"21,1,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-112\"\u003ePurge Gas Dependency for Corrosive Processes:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-112\"\u003e Because this pump is the \u003c\/span\u003e\u003cb data-path-to-node=\"21,1,0,0\" data-index-in-node=\"71\"\u003e\u003cspan class=\"citation-112\"\u003eLMC\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-112 citation-end-112\"\u003e chemical configuration, a continuous dry Nitrogen (\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"126\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-111 citation-end-111\"\u003e) purge flow of 20 to 30 mL\/min must be maintained at the purge port whenever corrosive gas handling or semiconductor etching processes are active.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Failure to maintain positive purge pressure can cause volatile compounds to migrate into the motor enclosure, destroying internal winding insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,1,0\"\u003e\u003cb data-path-to-node=\"21,1,1,0\" data-index-in-node=\"0\"\u003eInterconnect Hot-Plugging Hazard:\u003c\/b\u003e Under no circumstances should the 3-meter umbilical cable be coupled or uncoupled while the main \u003cb data-path-to-node=\"21,1,1,0\" data-index-in-node=\"131\"\u003eEI-D3403M\u003c\/b\u003e controller is energized or plugged into mains utility power. High residual voltages residing across the internal capacitors can arc upon pin separation, permanently destructive to both the controller's levitation sensing electronics and the pump's magnetic coils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,2,0\" id=\"p-rc_9469951dfb34f2d1-72\"\u003e\u003cb data-path-to-node=\"21,1,2,0\" data-index-in-node=\"0\"\u003eWater Line Cleanliness \u0026amp; Pressure Scaling:\u003c\/b\u003e\u003cspan class=\"citation-110 citation-end-110\"\u003e Ensure cooling water supply lines fall strictly within the \u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"5^\\circ\\text{C}\" data-index-in-node=\"102\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e5\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mbin mtight\"\u003e∘\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-109 citation-end-109\"\u003e to \u003csup class=\"superscript\" data-turn-source-index=\"20\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"30^\\circ\\text{C}\" data-index-in-node=\"121\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e3\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mbin mtight\"\u003e∘\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-108 citation-end-108\"\u003e parameters and do not exceed 0.5 MPa.\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Thermal over-temperature sensors in the pump base will trigger a hard protective motor trip on the controller deck if scaling or flow constriction reduces cooling efficiency.\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/blockquote\u003e\n\u003ch2 data-path-to-node=\"23\"\u003e4. Target Cleanroom \u0026amp; Manufacturing Deployments\u003c\/h2\u003e\n\u003cul data-path-to-node=\"24\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,0,0\"\u003e\u003cb data-path-to-node=\"24,0,0\" data-index-in-node=\"0\"\u003eReactive Ion Etching (RIE) \u0026amp; Plasma CVD:\u003c\/b\u003e Engineered to manage continuous process gas loads under corrosive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,1,0\"\u003e\u003cb data-path-to-node=\"24,1,0\" data-index-in-node=\"0\"\u003eElectron Microscopy \u0026amp; Surface Science Chambers:\u003c\/b\u003e Ideal for analytical setups demanding extremely low vibration footprints and strict oil-free cross-contamination limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"24,2,0\"\u003e\u003cb data-path-to-node=\"24,2,0\" data-index-in-node=\"0\"\u003eIndustrial Coating Applications:\u003c\/b\u003e High-volume throughput stabilization for large batch architectural or optical thin-film deposition lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Shimadzu","offers":[{"title":"Default Title","offer_id":46811191509181,"sku":null,"price":10989.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/ShimadzuTMP2203Blurred.jpg?v=1775102615"},{"product_id":"pfeiffer-vacuum-tmh-071-p-turbomolecular-pump","title":"Pfeiffer Vacuum TMH 071 P Turbomolecular Pump","description":"\u003cp id=\"p-rc_f687e0d4023e856f-130\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-239\"\u003eThe \u003c\/span\u003e\u003cb data-index-in-node=\"4\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-239\"\u003ePfeiffer TMH 071 P\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-239 citation-end-239\"\u003e is a robust, compact turbomolecular drag pump engineered for high-reliability applications across both industrial processing and precision analytical laboratories.\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-238\"\u003eKnown for its exceptional mechanical endurance, the TMH 071 P utilizes Pfeiffer's classic \u003c\/span\u003e\u003cb data-index-in-node=\"277\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-238\"\u003ehybrid bearing architecture\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-238 citation-end-238\"\u003e: a wear-free permanent magnetic bearing on the high-vacuum side paired with a heavy-duty, oil-lubricated ceramic ball bearing on the foreline\/backing side.\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-131\" data-path-to-node=\"5\"\u003e\u003cspan class=\"citation-237\"\u003eThis specific part number (\u003c\/span\u003e\u003cb data-index-in-node=\"27\" data-path-to-node=\"5\"\u003e\u003cspan class=\"citation-237\"\u003ePM P03 201\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-237\"\u003e) features a \u003c\/span\u003e\u003cb data-index-in-node=\"50\" data-path-to-node=\"5\"\u003e\u003cspan class=\"citation-237\"\u003eDN 63 ISO-K high-vacuum inlet flange\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-237\"\u003e and comes equipped with a modern integrated \u003c\/span\u003e\u003cb data-index-in-node=\"131\" data-path-to-node=\"5\"\u003e\u003cspan class=\"citation-237\"\u003eTC 750\/TC-750-E74 electronic drive unit\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-237 citation-end-237\"\u003e, providing compact onboard control and enhanced interface safety protocols.\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-236 citation-end-236\"\u003eThe \"P\" suffix designates an integrated purge\/sealing gas connection port, enabling active protection of the motor and internal bearing assembly against particulate ingress or aggressive media process variables.\u003csup data-turn-source-index=\"5\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-132\" data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003ePart Number (MPN):\u003c\/b\u003e \u003cspan class=\"citation-235 citation-end-235\"\u003ePM P03 201 (Cross-references: 2000016925 \/ PM C01 712)\u003csup data-turn-source-index=\"6\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-133\" data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eHigh Vacuum Inlet Flange:\u003c\/b\u003e \u003cspan class=\"citation-234 citation-end-234\"\u003eDN 63 ISO-K\u003csup data-turn-source-index=\"7\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-134\" data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eFore-Vacuum \/ Exhaust Flange:\u003c\/b\u003e \u003cspan class=\"citation-233 citation-end-233\"\u003eDN 16 ISO-KF\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-135\" data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eDrive Electronics:\u003c\/b\u003e \u003cspan class=\"citation-232 citation-end-232\"\u003eTC 750\/750-E74 controller\u003csup data-turn-source-index=\"9\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"8\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-136\" data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eProven Hybrid Bearings:\u003c\/b\u003e \u003cspan class=\"citation-231 citation-end-231\"\u003eThe permanent magnetic upper bearing runs completely touch-free to eliminate wear and vibration on the high-vacuum side, while the bottom ceramic bearing delivers reliable fore-vacuum side radial stability.\u003csup data-turn-source-index=\"10\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003ePurge Gas Protection:\u003c\/b\u003e Built-in purge port enables metered sealing gas line integration, actively preventing backing-stream contaminants or minor process chemistry from entering the motor well.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eUltra-Fast Acceleration:\u003c\/b\u003e High-torque internal motor geometry achieves a full operational speed of \u003cb data-index-in-node=\"98\" data-path-to-node=\"9,2,0\"\u003e90,000 rpm\u003c\/b\u003e in under \u003cb data-index-in-node=\"118\" data-path-to-node=\"9,2,0\"\u003e2 minutes\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-137\" data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eIntegrated TC 750 Drive Unit:\u003c\/b\u003e Eliminates the need for bulky external rack-mount controllers; \u003cspan class=\"citation-230 citation-end-230\"\u003eaccepts direct 24 V DC supply power and provides robust fault, interlock, and speed diagnostics.\u003csup data-turn-source-index=\"11\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eFlexible Cooling Profiles:\u003c\/b\u003e Standard passive convection cooling can be augmented via accessory forced-air fan assemblies or direct-mount water-cooling blocks based on process gas load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"11\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv data-ved=\"0CAAQ3ecQahgKEwiJob7ymaCVAxUAAAAAHQAAAAAQuQI\" data-hveid=\"0\" class=\"table-content\"\u003e\n\u003ctable data-path-to-node=\"12\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"12,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"12,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0,0\"\u003ePumping Speed (\u003cspan data-index-in-node=\"15\" data-math=\"N_2\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,1,0\"\u003e33 l\/s to 60 l\/s (varies by backing configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0,0\"\u003eNominal Rotation Speed\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,1,0\"\u003e90,000 rpm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,3,0,0\"\u003eUltimate Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,1,0\"\u003e\u0026lt; \u003cspan data-index-in-node=\"2\" data-math=\"1 \\times 10^{-7}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−7\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e mbar (unbaked) \/ \u0026lt; \u003cspan data-index-in-node=\"38\" data-math=\"7.5 \\times 10^{-8}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e7.5\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e Torr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,4,0,0\"\u003eCompression Ratio (\u003cspan data-index-in-node=\"19\" data-math=\"N_2\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,1,0\"\u003e\u0026gt; \u003cspan data-index-in-node=\"2\" data-math=\"1 \\times 10^{11}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e11\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,5,0,0\"\u003eStart-Up \/ Run-Up Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"\\le\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 2.0 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,6,0,0\"\u003eInput Connection Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,1,0\"\u003e24 V DC (\u003cspan data-index-in-node=\"9\" data-math=\"\\pm\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e5%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,7,0,0\"\u003eSealing Gas (Purge) Max Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,1,0\"\u003e2 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,8,0,0\"\u003eMax Permissible Rotor Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,1,0\"\u003e80 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,9,0,0\"\u003eRecommended Backing Pumps\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,9,1,0\"\u003eMVP 015-2 \/ DUO 2.5 \/ DUO 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,10,0,0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,10,1,0\"\u003e3.2 kg (7.05 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"14\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eThe physical footprint and sealing-gas readiness of the TMH 071 P make it an excellent choice for legacy tool support and modern integrations alike:\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,0,0\"\u003eAnalytical Equipment:\u003c\/b\u003e Mass Spectrometers (GC-MS), residual gas analyzers (RGAs), and helium leak detection benches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,1,0\"\u003eVacuum Processing:\u003c\/b\u003e Thin-film desktop coaters, sputter deposition systems, and plasma etching tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_f687e0d4023e856f-138\" data-path-to-node=\"16,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,2,0\"\u003eR\u0026amp;D Environments:\u003c\/b\u003e \u003cspan class=\"citation-229 citation-end-229\"\u003eUHV high-energy physics beamlines, clean auxiliary backing systems, and space simulation test chambers.\u003csup data-turn-source-index=\"12\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":46990066942141,"sku":null,"price":6450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PferifferTMH071P_1.jpg?v=1783533033"},{"product_id":"ebara-306w-tf-turbomolecular-pump-controller","title":"Ebara 306W-TF Turbomolecular Pump Controller","description":"\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003eEbara 306W-TF\u003c\/b\u003e (Part Number: \u003cb data-path-to-node=\"6\" data-index-in-node=\"32\"\u003eAET08-4490C\u003c\/b\u003e) is a high-performance, precision turbomolecular pump controller engineered to drive and monitor Ebara's advanced vacuum systems. Designed for industrial reliability and seamless tool integration, this controller ensures stable rotor acceleration, precise speed regulation, and advanced fault detection for critical semiconductor, analytical, and high-vacuum laboratory processes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eWith comprehensive interface options and robust internal safety interlocks, the AET08-4490C provides optimal power management and protection against power fluctuations, overcurrent, and thermal overload.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjc3tW-8aKVAxUAAAAAHQAAAAAQoQI\"\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eEbara Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003e306W-TF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003eAET08-4490C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eProduct Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003eTurbomolecular Pump Controller \/ Frequency Converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e\u003ccode data-path-to-node=\"10,5,1,0\" data-index-in-node=\"0\"\u003e[e.g., Single-Phase 200-240 VAC]\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eOutput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003eHigh-frequency AC drive optimized for Ebara turbo series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eCooling\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003eForced Air (Internal Fan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eInterface \/ Communication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e\u003ccode data-path-to-node=\"10,8,1,0\" data-index-in-node=\"0\"\u003e[e.g., Remote I\/O, RS-232C, or Serial - please verify your unit's rear ports]\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003eStandard rack-mount \/ compact enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e\u003ccode data-path-to-node=\"10,10,1,0\" data-index-in-node=\"0\"\u003e[Insert Weight, e.g., Approx. 12 lbs \/ 5.4 kg]\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"12\"\u003e\n\u003cbr\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003ePrecise Frequency Matching:\u003c\/b\u003e Delivers clean, optimized high-frequency power output to ensure smooth acceleration and steady-state operation of the turbo pump.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eAdvanced Diagnostics \u0026amp; Interlocks:\u003c\/b\u003e Continuous monitoring of motor temperature, bearing conditions, and current draw protects your high-vacuum equipment from catastrophic failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eSeamless Tool Integration:\u003c\/b\u003e Equipped with standard logic I\/O interfaces for seamless remote control, status feedback, and emergency-off system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eRobust Enclosure Design:\u003c\/b\u003e Built to withstand the rigorous electrical and thermal demands of semiconductor cleanrooms and industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eCompatible Pump Models\u003c\/h2\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eOptimized for use with \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"23\"\u003eEbara 306 series\u003c\/b\u003e turbomolecular pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ebara","offers":[{"title":"Default Title","offer_id":47008195936445,"sku":null,"price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/Ebara306W-TF_1.jpg?v=1782414327"},{"product_id":"edwards-stp-ix455-turbomolecular-pump","title":"Edwards STP-iX455 Turbomolecular Pump","description":"\u003cp data-path-to-node=\"5\"\u003eThe \u003cb data-path-to-node=\"5\" data-index-in-node=\"4\"\u003eEdwards STP-iX455\u003c\/b\u003e represents the pinnacle of high-vacuum engineering, featuring an advanced, digitally controlled \u003cb data-path-to-node=\"5\" data-index-in-node=\"118\"\u003e5-axis magnetic levitation system\u003c\/b\u003e paired with a fully \u003cb data-path-to-node=\"5\" data-index-in-node=\"172\"\u003eintegrated onboard controller\u003c\/b\u003e. By eliminating the need for bulky, traditional rack-mounted control units and heavy interconnecting cables, this all-in-one design delivers an exceptionally small footprint and dramatically simplifies tool integration.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003eDesigned specifically for vibration-sensitive and high-uptime environments—such as electron microscopy, metrology, lithography, and high-energy physics research—the STP-iX455 offers an unparalleled clean, hydrocarbon-free high vacuum with virtually zero routine maintenance.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eIntegrated Drive Controller:\u003c\/b\u003e True plug-and-play architecture reduces installation costs and saves valuable rack space. Operates on a standard \u003cspan class=\"math-inline\" data-math=\"48\\text{V DC}\" data-index-in-node=\"142\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e48\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e input (compatible with the Edwards iPS-240 AC power supply unit).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eUltra-Low Vibration:\u003c\/b\u003e The self-sensing magnetic bearing system combined with Automatic Vibration Reduction (AVR) delivers a \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"123\"\u003e50% reduction in vibration\u003c\/b\u003e amplitudes compared to previous-generation turbo pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eMaintenance-Free Operation:\u003c\/b\u003e Zero frictional contact points mean no bearing wear, no oil lubrication requirements, and zero risk of process contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eFlexible Orientation:\u003c\/b\u003e Can be mounted and operated reliably in any physical orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eAdvanced Diagnostics:\u003c\/b\u003e Real-time monitoring and digital interface capabilities ensure maximum tool uptime and early anomaly detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eSection 2: Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahcKEwjrv6q686yVAxUAAAAAHQAAAAAQfg\"\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eEdwards Vacuum (Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eSTP-iX455 (High-Vacuum Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e\u003cb data-path-to-node=\"10,3,1,0\" data-index-in-node=\"0\"\u003ePT64-02-050\u003c\/b\u003e (\u003cb data-path-to-node=\"10,3,1,0\" data-index-in-node=\"13\"\u003ePT6402050\u003c\/b\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eHigh-Vacuum Inlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e\u003cb data-path-to-node=\"10,4,1,0\" data-index-in-node=\"0\"\u003eDN 100 CF (ConFlat Flange)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eForeline \/ Backing Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003eDN 25 KF (NW25)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003ePumping Speed (\u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"450\\text{ l\/s}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e450\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e l\/s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Peak class-leading performance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003ePumping Speed (\u003cspan class=\"math-inline\" data-math=\"H_2\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eH\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"300\\text{ l\/s}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e300\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e l\/s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eCompression Ratio (\u003cspan class=\"math-inline\" data-math=\"N_2\" data-index-in-node=\"19\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt; 10^8\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026gt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eCompression Ratio (\u003cspan class=\"math-inline\" data-math=\"H_2\" data-index-in-node=\"19\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eH\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt; 1 \\times 10^4\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026gt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e4\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eUltimate Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"6.5 \\times 10^{-6}\\text{ Pa}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e6.5\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−6\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"5 \\times 10^{-8}\\text{ Torr}\" data-index-in-node=\"30\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e5\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Torr\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003e\u003cb data-path-to-node=\"10,11,0,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"1.3 \\times 10^{-1}\\text{ Pa}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1.3\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−1\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003e\u003cb data-path-to-node=\"10,12,0,0\" data-index-in-node=\"0\"\u003eAllowable Backing Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"67\\text{ Pa}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e67\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,0,0\"\u003e\u003cb data-path-to-node=\"10,13,0,0\" data-index-in-node=\"0\"\u003eRated Rotational Speed\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"55,000\\text{ RPM}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e55\u003c\/span\u003e\u003cspan class=\"mpunct\"\u003e,\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e000\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e RPM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,0,0\"\u003e\u003cb data-path-to-node=\"10,14,0,0\" data-index-in-node=\"0\"\u003eRun-up \/ Starting Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026lt; 6\\text{ minutes}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e6\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e minutes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,15,0,0\"\u003e\u003cb data-path-to-node=\"10,15,0,0\" data-index-in-node=\"0\"\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,15,1,0\"\u003eNatural Convection (Air\/Water assist options for heavy gas loads or baking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,16,0,0\"\u003e\u003cb data-path-to-node=\"10,16,0,0\" data-index-in-node=\"0\"\u003ePower Requirements\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,16,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"48\\text{V DC}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e48\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,17,0,0\"\u003e\u003cb data-path-to-node=\"10,17,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,17,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"15\\text{ kg}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e15\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e kg\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"33\\text{ lbs}\" data-index-in-node=\"14\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e33\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e lbs\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,18,0,0\"\u003e\u003cb data-path-to-node=\"10,18,0,0\" data-index-in-node=\"0\"\u003eCompliance \u0026amp; Safety\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,18,1,0\"\u003eUL Listed, CE Marked, SEMI S2 Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"12\"\u003e\u003c\/h2\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003eElectron Microscopes (SEM, TEM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eSurface Science \u0026amp; Analytical Instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eMetrology and Lithography Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003eThin Film Deposition (PVD, Sputtering)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003eHigh-Energy Physics \u0026amp; R\u0026amp;D Laboratory Vacuum Chambers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47029438578877,"sku":null,"price":12499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSTP-iX455_1.jpg?v=1782751882"},{"product_id":"leybold-turbo-drive-td-400-frequency-converter-pump-controller","title":"Leybold TURBO.DRIVE TD 400 Frequency Converter Pump Controller","description":"\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"3\"\u003eLeybold TURBO.DRIVE TD 400\u003c\/b\u003e is a highly compact, micro-controlled electronic frequency converter designed to power, control, and monitor Leybold's premier series of mechanical bearing turbomolecular vacuum pumps.\u003c\/p\u003e\n\u003cp id=\"p-rc_868cb305330b2682-58\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-115\"\u003eThis specific model variation (\u003c\/span\u003e\u003cb data-index-in-node=\"31\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-115\"\u003ePart Number: 800073V0002\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-115\"\u003e) features an integrated \u003c\/span\u003e\u003cb data-index-in-node=\"80\" data-path-to-node=\"4\"\u003e\u003cspan class=\"citation-115\"\u003eRS-232 digital serial communication interface\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-115 citation-end-115\"\u003e, making it ideal for streamlined automation setups, host PC communication, data logging, and remote status monitoring.\u003csup data-turn-source-index=\"1\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-114 citation-end-114\"\u003eOperating on a space-saving \u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan data-index-in-node=\"273\" data-math=\"24\\text{V DC}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e24\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-113 citation-end-113\"\u003e supply voltage, the TD 400 can be mounted directly to the side or bottom of a compatible pump using an accessory docking kit, or mounted remotely via an interconnecting cable link.\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eIntelligent Pump Control:\u003c\/b\u003e Microprocessor tracking adjusts drive frequency automatically during gas load variations and acceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eRS-232 Communication Interface:\u003c\/b\u003e Allows direct serial interaction with PC platforms, PLC systems, or external instrumentation tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-59\" data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eFlexible Mounting Architecture:\u003c\/b\u003e Extremely low footprint; \u003cspan class=\"citation-112 citation-end-112\"\u003eattaches directly onto the pump chassis or installs remotely to adapt to restricted equipment bays.\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eComprehensive Self-Diagnostics:\u003c\/b\u003e Constantly monitors internal temperature, rotation velocity window, current draw, and error profiles to protect the structural integrity of the pump.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-60\" data-path-to-node=\"5,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,4,0\"\u003eSafety First Design:\u003c\/b\u003e \u003cspan class=\"citation-111 citation-end-111\"\u003eComplies strictly with standard SELV (Safety Extra Low Voltage) protective insulation parameters.\u003csup data-turn-source-index=\"5\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eTechnical Specifications \u0026amp; Pump Compatibility\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv data-ved=\"0CAAQ3ecQahgKEwjf-KX08a-VAxUAAAAAHQAAAAAQjAM\" data-hveid=\"0\" class=\"table-content\"\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0,0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eLeybold Vacuum (Germany)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0,0\"\u003eModel Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eTURBO.DRIVE TD 400 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0,0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,1,0\"\u003e800073V0002\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,4,0,0\"\u003eCommunication Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,4,1,0\"\u003eRS-232 Serial Port Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,5,0,0\"\u003eSupply Voltage Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"24\\text{V DC} \\pm 5\\%\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e24\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV DC\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e±\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e5%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,6,0,0\"\u003eMaximum Output Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e3-phase, \u003cspan data-index-in-node=\"9\" data-math=\"3 \\times 24\\text{V}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e3\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e24\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eV\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e drive signal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,7,0,0\"\u003eMax Current Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003eUp to \u003cspan data-index-in-node=\"6\" data-math=\"8\\text{ A DC}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e8\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e A DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (pump dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,8,0,0\"\u003eMax Continuous Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"190\\text{ W}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e190\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (requires \u003cspan data-index-in-node=\"23\" data-math=\"200\\text{ W}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e200\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e overhead supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,9,0,0\"\u003eRelay I\/O Contact Capability\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"42\\text{ V}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e42\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e, \u003cspan data-index-in-node=\"13\" data-math=\"0.5\\text{ A}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0.5\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e A\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,10,0,0\"\u003eProtection Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,11,0,0\"\u003eDimensions (W x H x D)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"100\\text{ mm} \\times 90\\text{ mm} \\times 100\\text{ mm}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e100\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mm\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e90\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mm\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e100\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,12,0,0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"0.7\\text{ kg}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0.7\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e kg\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan data-index-in-node=\"15\" data-math=\"1.5\\text{ lbs}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1.5\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e lbs\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-footer hide-on-print hide-from-message-actions\"\u003e\n\u003cbutton aria-label=\"More options\" class=\"mdc-icon-button mat-mdc-icon-button mat-mdc-button-base mat-badge mat-unthemed mat-badge-overlap mat-badge-above mat-badge-after mat-badge-small mat-badge-hidden ng-star-inserted\"\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-icon-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003c\/button\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eApproved Factory Pump Compatibility:\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-61\" data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eTURBOVAC SL Family:\u003c\/b\u003e \u003cspan class=\"citation-110 citation-end-110\"\u003eSL 80, SL 300\u003csup data-turn-source-index=\"6\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-62\" data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eTURBOVAC TW Family:\u003c\/b\u003e \u003cspan class=\"citation-109 citation-end-109\"\u003eTW 70 H, TW 250 S, TW 300, TW 300 H\u003csup data-turn-source-index=\"7\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-63\" data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eTURBOVAC S Family:\u003c\/b\u003e \u003cspan class=\"citation-108 citation-end-108\"\u003eTW 220\/150 S, TW 220\/150\/15 S\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eSection 3: Applications \u0026amp; Integration\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_868cb305330b2682-64\" data-path-to-node=\"13,0,0\"\u003e\u003cspan class=\"citation-107 citation-end-107\"\u003eAnalytical Lab Equipment Systems (Mass Spectrometers, Leak Detectors)\u003csup data-turn-source-index=\"9\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eCustom R\u0026amp;D UHV Chambers and Pumping Stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eSemiconductor Cleanroom Process Integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003eIndustrial High-Vacuum Tooling Controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leybold","offers":[{"title":"Default Title","offer_id":47169373044925,"sku":null,"price":1095.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/LeyboldTD400_1.jpg?v=1782924016"},{"product_id":"adixen-mag-power-controller-1","title":"Adixen MAG Power Controller","description":"\u003cp\u003eThis \u003cb\u003eAdixen MAG Power Controller\u003c\/b\u003e is the ideal solution for operating and monitoring your magnetically levitated turbomolecular pumps. Designed for high-performance vacuum systems, this controller provides reliable and precise control for a range of demanding applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDigital External Drive Electronics:\u003c\/b\u003e Offers advanced control and monitoring capabilities for your vacuum system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Design:\u003c\/b\u003e At a 1\/2 of 19\" rack size, it saves valuable space in your equipment setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-7\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-7\"\u003eFull Pump Interoperability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003e Designed to be fully interchangeable with various Adixen ATH-M and ATP-M series pumps, ensuring flexibility and ease of integration.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAdvanced Safety Features:\u003c\/b\u003e The controller is engineered with a battery-free system, where in case of a power failure, the pump's rotor generates power to maintain levitation, ensuring a safe and controlled shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComprehensive Pump Monitoring:\u003c\/b\u003e The unit provides a digital display for operating and troubleshooting parameters, including speed, power consumption, and temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button\"\u003e\n\u003cdiv class=\"table-content not-end-of-paragraph\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjDpPzdms-PAxUAAAAAHQAAAAAQlQI\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAdixen (Pfeiffer Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMAG Power Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200-240 V, 50\/60 Hz, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Power Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kW (with heater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions (L x W x H)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e450 mm x 219 mm x 132.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg (19 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSupported Pumps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAdixen ATH-M and ATP-M series (excluding ATH 500 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Alcatel","offers":[{"title":"Default Title","offer_id":47169596096701,"sku":null,"price":6289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/AdixenMAGPower_3.jpg?v=1782929294"},{"product_id":"edwards-scu-1500-universal-digital-stp-turbomolecular-pump-controller","title":"Edwards SCU-1500 Universal Digital STP Turbomolecular Pump Controller","description":"\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eEdwards SCU-1500\u003c\/b\u003e (originally designed under the Seiko Seiki banner) is a high-capacity, fully digital \u003cb data-path-to-node=\"3\" data-index-in-node=\"106\"\u003e5-axis magnetic bearing controller\u003c\/b\u003e engineered to operate heavy-duty, high-throughput STP series turbomolecular vacuum pumps. This controller is famous for its exceptional reliability in high-uptime industrial semiconductor fabrication lines, plasma etching, and chemical vapor deposition (CVD) environments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe SCU-1500 features an advanced \u003cb data-path-to-node=\"4\" data-index-in-node=\"34\"\u003e3-phase brushless DC motor driving network\u003c\/b\u003e paired with proactive magnetic suspension monitoring. It continuously samples the position sensors of the pump's rotor, processing multi-axis balance adjustments in real time to guarantee ultra-low vibration harmonics. It includes native support for an integrated \u003cb data-path-to-node=\"4\" data-index-in-node=\"341\"\u003eTemperature Management System (TMS)\u003c\/b\u003e to regulate internal pump temperatures and eliminate chemical condensation or byproduct deposition during aggressive gas processing.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eAdvanced 5-Axis Magnetic Stabilization:\u003c\/b\u003e Active microprocessor monitoring ensures friction-free levitation, eliminating bearing wear and background vibrational interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eIntegrated TMS Control Unit:\u003c\/b\u003e Direct logic connectivity handles internal pump heaters and cooling parameters to manage corrosive process gas environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eIndustrial Noise Immunity:\u003c\/b\u003e Excellent EMC isolation shielding guards against electrical line disruptions typical of semiconductor cleanrooms and industrial facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eComprehensive Automated Safeguards:\u003c\/b\u003e Real-time interlock protection for pump overheating, electrical overload, rotational overspeed, power failures, and levitation anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eRobust Communication \u0026amp; Control Arrays:\u003c\/b\u003e Supports automated remote operations via extensive parallel I\/O links alongside dedicated RS-232C\/RS-485 serial interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eTechnical Specifications \u0026amp; Pump Compatibility\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjf-KX08a-VAxUAAAAAHQAAAAAQuAM\"\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"8,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eEdwards Vacuum (Originally Seiko Seiki, Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-path-to-node=\"8,2,0,0\" data-index-in-node=\"0\"\u003eModel Array\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eSCU-1500 Control Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-path-to-node=\"8,3,0,0\" data-index-in-node=\"0\"\u003eCommon Part Numbers\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e\u003cb data-path-to-node=\"8,3,1,0\" data-index-in-node=\"0\"\u003ePT59-ZS-Z00\u003c\/b\u003e | \u003cb data-path-to-node=\"8,3,1,0\" data-index-in-node=\"14\"\u003ePT59Z1Z00\u003c\/b\u003e (TELIUS Track \/ OEM Spec Variations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-path-to-node=\"8,4,0,0\" data-index-in-node=\"0\"\u003ePrimary Input Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"200\\text{ to }240\\text{ VAC } (\\pm10\\%)\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e200\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e to \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e240\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e VAC \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mopen\"\u003e(\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003cspan class=\"mclose\"\u003e)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e, Single-Phase, \u003cspan class=\"math-inline\" data-math=\"50\/60\\text{ Hz}\" data-index-in-node=\"55\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e50\/60\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Hz\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-path-to-node=\"8,5,0,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"1,500\\text{ VA}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mpunct\"\u003e,\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e500\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e VA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e max (Base mode) | Up to \u003cspan class=\"math-inline\" data-math=\"$2,100\\text{ VA\" data-index-in-node=\"40\"\u003e\u003cspan class=\"katex-error\" title=\"ParseError: KaTeX parse error: Can't use function '$' in math mode at position 1: $̲2,100\\text{ VA\"\u003e$2,100\\text{ VA\u003c\/span\u003e\u003c\/span\u003e (With active TMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003e\u003cb data-path-to-node=\"8,6,0,0\" data-index-in-node=\"0\"\u003eMotor Drive Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e3-Phase Brushless DC, Up to \u003cspan class=\"math-inline\" data-math=\"80\\text{ VAC}\" data-index-in-node=\"28\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e80\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e VAC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e at \u003cspan class=\"math-inline\" data-math=\"550\\text{ Hz}\" data-index-in-node=\"45\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e550\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Hz\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003e\u003cb data-path-to-node=\"8,7,0,0\" data-index-in-node=\"0\"\u003eFront Panel Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e2x20 Character Backlit LCD screen with tactile parameter keys\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003e\u003cb data-path-to-node=\"8,8,0,0\" data-index-in-node=\"0\"\u003eStatus LED Displays\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003ePower, Accel, Normal, Brake, Temp Ctrl, Remote, Failure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003e\u003cb data-path-to-node=\"8,9,0,0\" data-index-in-node=\"0\"\u003eSerial Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e9-pin RS-232C \/ RS-485 Interface connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003e\u003cb data-path-to-node=\"8,10,0,0\" data-index-in-node=\"0\"\u003eMass \/ Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"11.0\\text{ kg}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e11.0\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e kg\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"24.2\\text{ lbs}\" data-index-in-node=\"16\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e24.2\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e lbs\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eCertified STP Pump Head Compatibility:\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSTP-XA2703 Series\u003c\/b\u003e (Throughput Advanced Line)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eSTP-XA3203 Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSTP-A2203 \/ A2503 \/ A3003\u003c\/b\u003e Heavy-Duty Configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eApplications \u0026amp; Tooling Integration\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003eAdvanced Semiconductor Fabrications (Etch, CVD, PVD, Ashing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eHigh-Capacity Industrial Coaters and Flat Panel Display Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eExtreme Throughput Corrosive Gas Chemical R\u0026amp;D Operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003eTool integrations on Tokyo Electron (TEL) Telius track platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47169623359677,"sku":null,"price":6249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU1500_1.jpg?v=1782930398"},{"product_id":"edwards-scu-1600-turbomolecular-pump-controller","title":"Edwards SCU-1600 Turbomolecular Pump Controller","description":"\u003cp data-path-to-node=\"5\" id=\"p-rc_89235f795ce20a37-32\"\u003e\u003cspan class=\"citation-27\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-27\"\u003eEdwards SCU-1600\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-27 citation-end-27\"\u003e is a premium, fully digital controller engineered for high-capacity, magnetically levitated turbomolecular vacuum pumps.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-26 citation-end-26\"\u003eKnown for its exceptional reliability, low cost of ownership, and advanced communications, this unit serves as the backbone for high-demand industrial, semiconductor, and research vacuum systems.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp data-path-to-node=\"6\" id=\"p-rc_89235f795ce20a37-33\"\u003e\u003cspan class=\"citation-25\"\u003eThis specific model features a \u003c\/span\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"31\"\u003e\u003cspan class=\"citation-25\"\u003ebuilt-in Temperature Management System (TMS) control unit\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-25 citation-end-25\"\u003e, allowing for precise thermal optimization to prevent gas condensation and process-product deposition inside the pump mechanism.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_89235f795ce20a37-34\"\u003e\u003cspan class=\"citation-24\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-24\"\u003eUniversal High-Capacity Compatibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-24 citation-end-24\"\u003e Runs high-throughput STP turbo pumps ranging from 2,000 l\/s to 4,500 l\/s.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_89235f795ce20a37-35\"\u003e\u003cspan class=\"citation-23\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-23\"\u003eIntegrated TMS Control Unit:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-23 citation-end-23\"\u003e Built-in circuitry to regulate optional heating\/cooling management hardware directly.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_89235f795ce20a37-36\"\u003e\u003cspan class=\"citation-22\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-22\"\u003eFully Digital Control Architecture:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-22 citation-end-22\"\u003e Provides robust protection, real-time safety monitoring, and highly efficient 3-phase DC brushless motor driving.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_89235f795ce20a37-37\"\u003e\u003cspan class=\"citation-21\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-21\"\u003eAdvanced Safety Interlocks:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-21 citation-end-21\"\u003e Features automatic detection for electromagnetic bearing anomalies, pump overheat, motor driver overload, overspeed, power failure, and TMS loop faults.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eUser-Friendly Front Panel:\u003c\/b\u003e Equipped with a 2-line, 20-character LCD display for error-code diagnosing and clear state updates alongside intuitive manual push-button switches (\u003ccode data-path-to-node=\"8,4,0\" data-index-in-node=\"175\"\u003eSTART\u003c\/code\u003e, \u003ccode data-path-to-node=\"8,4,0\" data-index-in-node=\"182\"\u003eSTOP\u003c\/code\u003e, \u003ccode data-path-to-node=\"8,4,0\" data-index-in-node=\"188\"\u003eRESET\u003c\/code\u003e, \u003ccode data-path-to-node=\"8,4,0\" data-index-in-node=\"195\"\u003eSELECT\u003c\/code\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahcKEwit25Tsp8OVAxUAAAAAHQAAAAAQGw\"\u003e\n\u003ctable data-path-to-node=\"11\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"11,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"11,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,0,0\"\u003e\u003cb data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,1,0\"\u003eEdwards (Seiko Seiki OEM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,0,0\"\u003e\u003cb data-path-to-node=\"11,2,0,0\" data-index-in-node=\"0\"\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,1,0\"\u003eSCU-1600 \/ \u003cb data-path-to-node=\"11,2,1,0\" data-index-in-node=\"11\"\u003eYT76-Z0-Z20\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,0,0\"\u003e\u003cb data-path-to-node=\"11,3,0,0\" data-index-in-node=\"0\"\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,1,0\"\u003eSTP-A2203, STP-A2503\/A3003, STP-A2803\/A3503, STP-F2203, STP-XH2603\/XH3203, STP-XA2703\/XA3203, STP-XA4503, STP-XW3503\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,0,0\"\u003e\u003cb data-path-to-node=\"11,4,0,0\" data-index-in-node=\"0\"\u003eInput Voltage \/ Phase\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,1,0\"\u003e200–240 VAC \u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"12\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 10%, Single Phase (50\/60 Hz \u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"44\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 2 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,0,0\"\u003e\u003cb data-path-to-node=\"11,5,0,0\" data-index-in-node=\"0\"\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,1,0\"\u003e1,500 VA (without TMS active) \/ 2,100 VA (with TMS active)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,0,0\"\u003e\u003cb data-path-to-node=\"11,6,0,0\" data-index-in-node=\"0\"\u003eMain Breaker Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,1,0\"\u003e15 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,0,0\"\u003e\u003cb data-path-to-node=\"11,7,0,0\" data-index-in-node=\"0\"\u003eMotor Drive Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,1,0\"\u003e3-phase DC brushless driver (Max 80 VAC, Max 550 Hz normal operation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,0,0\"\u003e\u003cb data-path-to-node=\"11,8,0,0\" data-index-in-node=\"0\"\u003eSerial Communication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,1,0\"\u003eStandard RS-232 \/ RS-485 interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,0,0\"\u003e\u003cb data-path-to-node=\"11,9,0,0\" data-index-in-node=\"0\"\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,1,0\"\u003e132.5 mm \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"9\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e×\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 209.7 mm \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"25\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e×\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 498.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,0,0\"\u003e\u003cb data-path-to-node=\"11,10,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,1,0\"\u003e~11 kg (24.2 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch2 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eRear Interface Connections\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\" id=\"p-rc_89235f795ce20a37-38\"\u003e\u003cspan class=\"citation-20\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-20\"\u003eAC POWER:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-20 citation-end-20\"\u003e 3-pin input\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\" id=\"p-rc_89235f795ce20a37-39\"\u003e\u003cspan class=\"citation-19\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-19\"\u003eP.CONNECTOR (Pump Interconnect):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-19 citation-end-19\"\u003e 60-pin\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\" id=\"p-rc_89235f795ce20a37-40\"\u003e\u003cspan class=\"citation-18\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-18\"\u003eMOTOR:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-18 citation-end-18\"\u003e 8-pin\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\" id=\"p-rc_89235f795ce20a37-41\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eTMS (Temperature Management):\u003c\/b\u003e\u003cspan class=\"citation-17 citation-end-17\"\u003e 26-pin\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\" id=\"p-rc_89235f795ce20a37-42\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eREMOTE:\u003c\/b\u003e\u003cspan class=\"citation-16 citation-end-16\"\u003e 37-pin\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\" id=\"p-rc_89235f795ce20a37-43\"\u003e\u003cspan class=\"citation-15\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-15\"\u003eCOM Ports:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-15 citation-end-15\"\u003e Two 9-pin \"D\" type connectors (RS232\/RS485)\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\" id=\"p-rc_89235f795ce20a37-44\"\u003e\u003cspan class=\"citation-14\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14\"\u003eSTP-LINK:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14 citation-end-14\"\u003e 8-pin\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47612817146045,"sku":null,"price":6850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU1600_3.jpg?v=1783521813"},{"product_id":"pfeiffer-vacuum-tps-150-turbo-pump-power-supply-controller","title":"Pfeiffer Vacuum TPS 150 Turbo Pump Power Supply \u0026 Controller","description":"\u003cp data-path-to-node=\"4\" id=\"p-rc_062b6c09e8b89999-147\"\u003e\u003cspan class=\"citation-239\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-239\"\u003ePfeiffer Vacuum TPS 150\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-239 citation-end-239\"\u003e is a compact, high-efficiency electronic drive power supply unit designed specifically to power and interface with Pfeiffer’s series of high-vacuum turbomolecular pumps (such as the TMH\/TMU 071 series equipped with TC 600 or drive electronic nodes).\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Engineered for reliable continuous benchtop or system-integrated operation, this power supply unit provides the vital voltage stabilization and regulatory infrastructure required to manage high-speed rotor operations safely.\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp data-path-to-node=\"5\"\u003eFeaturing a robust, compact metal chassis with built-in short-circuit protection and thermal over-current safeguards, the TPS 150 ensures stable 24 VDC output under maximum operational load profiles. Its highly efficient heat dissipation design makes it ideal for dense equipment racks or tight laboratory bench placements where heat management is critical for sensitive experimental environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eUniversal Dual-Voltage Input:\u003c\/b\u003e Auto-ranging or switchable input functionality handles worldwide mains voltages effortlessly (90–132 VAC \/ 185–265 VAC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\" id=\"p-rc_062b6c09e8b89999-148\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDedicated 24 VDC Control Output:\u003c\/b\u003e \u003cspan class=\"citation-238 citation-end-238\"\u003eDelivers high-stability DC output up to 170 VA power consumption capacity, engineered to drive complex turbo electronics and integrated accessories smoothly.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eCompact Footprint \u0026amp; High Reliability:\u003c\/b\u003e Small component architecture minimizes rack or workspace footprint while providing premium industrial-grade electrical insulation (IP20 rated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eBuilt-in Safety Defenses:\u003c\/b\u003e Integrated current limit protection and thermal tracking protocols prevent voltage spikes from reaching internal pump components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwit25Tsp8OVAxUAAAAAHQAAAAAQ7gI\"\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003ePfeiffer Vacuum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eTPS 150\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e\u003cb data-path-to-node=\"10,3,1,0\" data-index-in-node=\"0\"\u003ePM 051 461-T\u003c\/b\u003e \/ \u003cb data-path-to-node=\"10,3,1,0\" data-index-in-node=\"15\"\u003ePM051461AT\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eConnection Voltage (Mains Input)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e90–132 VAC \/ 185–265 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e170 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eOutput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eInterface Connections\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e4-Pin standard output connection layout to Turbo Drive Electronics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eProtection Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e~62 mm x 100 mm x 180 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e~1.36 kg (3.0 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":47622710558909,"sku":null,"price":985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PfeifferTPS150_1.jpg?v=1783619000"},{"product_id":"pfeiffer-vacuum-dcu-001-display-control-unit","title":"Pfeiffer Vacuum DCU 001 Display \u0026 Control Unit","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003ePfeiffer Vacuum DCU 001 (P\/N: PM 041 816 BT)\u003c\/b\u003e is a compact display and control unit designed specifically to act as the primary interface for Pfeiffer Vacuum electronic turbomolecular drive controllers (such as the TC series). Engineered to serve as a reliable benchtop or 19-inch rack-integrated operating module, the DCU 001 enables lab personnel to easily adjust, monitor, and configure all critical turbo pump parameters in real time.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\" id=\"p-rc_8dcce4ba6655cd39-172\"\u003e\u003cspan class=\"citation-305\"\u003eThis is the \u003c\/span\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"12\"\u003e\u003cspan class=\"citation-305\"\u003eBasic Unit variant\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-305\"\u003e configured to operate \u003c\/span\u003e\u003ci data-path-to-node=\"5\" data-index-in-node=\"53\"\u003e\u003cspan class=\"citation-305\"\u003ewithout\u003c\/span\u003e\u003c\/i\u003e\u003cspan class=\"citation-305 citation-end-305\"\u003e its own integrated internal mains power transformer grid.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003c\/span\u003eInstead, it draws its raw working 24VDC operating voltage dynamically through the standard RS-485 serial data connection link directly from the pump's accompanying electronic drive unit. This design minimizes footprint, lowers heat dissipation on active lab benches, and streamlines cabling.\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe front interface features a high-contrast, easily scannable display that reports real-time system status metrics, including rotor rotational speed, current power consumption, error diagnostics, and backing pump states.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_8dcce4ba6655cd39-173\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eComprehensive Parameter Access:\u003c\/b\u003e \u003cspan class=\"citation-304 citation-end-304\"\u003eProvides complete oversight and diagnostic control over connected Pfeiffer TC electronic drive units and optional peripherals.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_8dcce4ba6655cd39-174\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eRS-485 Parasitic Power Layout:\u003c\/b\u003e \u003cspan class=\"citation-303 citation-end-303\"\u003eEliminates additional bulky AC power bricks by drawing utility voltage straight through the serial data cable from the pump controller.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_8dcce4ba6655cd39-175\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003ePeripheral System Configuration:\u003c\/b\u003e \u003cspan class=\"citation-302 citation-end-302\"\u003eSupports easy manual configuration of auxiliary equipment, including TMP backing\/air cooling fans, venting valves, and automated heating jackets.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_8dcce4ba6655cd39-176\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eRugged, Modular Integration:\u003c\/b\u003e \u003cspan class=\"citation-301 citation-end-301\"\u003eSized ideally for space-saving integration into specialized instrumentation rows or standard 19-inch\/3HE sub-rack enclosures.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwit25Tsp8OVAxUAAAAAHQAAAAAQtQM\"\u003e\n\u003ctable data-path-to-node=\"11\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"11,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"11,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,0,0\"\u003e\u003cb data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,1,0\"\u003ePfeiffer Vacuum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,0,0\"\u003e\u003cb data-path-to-node=\"11,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,1,0\"\u003eDCU 001 (Display Control Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,0,0\"\u003e\u003cb data-path-to-node=\"11,3,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,1,0\"\u003e\u003cb data-path-to-node=\"11,3,1,0\" data-index-in-node=\"0\"\u003ePM 041 816 BT\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,0,0\"\u003e\u003cb data-path-to-node=\"11,4,0,0\" data-index-in-node=\"0\"\u003eOperating Input Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,1,0\"\u003e12–30 VDC (Supplied via RS-485 line from TC unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,0,0\"\u003e\u003cb data-path-to-node=\"11,5,0,0\" data-index-in-node=\"0\"\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\\le\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,0,0\"\u003e\u003cb data-path-to-node=\"11,6,0,0\" data-index-in-node=\"0\"\u003eCommunication Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,1,0\"\u003eRS-485 serial bus layout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,0,0\"\u003e\u003cb data-path-to-node=\"11,7,0,0\" data-index-in-node=\"0\"\u003eHousing Dimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,1,0\"\u003eStandard panel layout fitting 19\" rack infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,0,0\"\u003e\u003cb data-path-to-node=\"11,8,0,0\" data-index-in-node=\"0\"\u003eEnclosure Protection Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,1,0\"\u003eIP20 \/ VDE 0411\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,0,0\"\u003e\u003cb data-path-to-node=\"11,9,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,1,0\"\u003e~0.45 kg (1.0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":47629434749117,"sku":null,"price":1249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PfeifferDCU001_1.jpg?v=1783705629"},{"product_id":"varian-turbo-v-301-navigator-turbomolecular-vacuum-pump-with-integrated-controller","title":"Varian Turbo-V 301 Navigator Turbomolecular Vacuum Pump with Integrated Controller","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eVarian Turbo-V 301 Navigator\u003c\/b\u003e is a highly efficient, mid-capacity turbomolecular vacuum pump engineered for demanding high- and ultra-high vacuum (UHV) applications. This listing represents a \u003cb data-path-to-node=\"4\" data-index-in-node=\"195\"\u003efully integrated vacuum solution\u003c\/b\u003e, featuring the specialized, compact \u003cb data-path-to-node=\"4\" data-index-in-node=\"264\"\u003eNavigator Controller attached directly to the base of the pump chassis\u003c\/b\u003e. This \"plug-and-pump\" configuration minimizes laboratory rack footprint, drastically simplifies cabling, and optimizes system space.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eEquipped with Varian's proprietary \u003cb data-path-to-node=\"5\" data-index-in-node=\"35\"\u003eMacroTorr® dynamic staging technology\u003c\/b\u003e, the Turbo-V 301 delivers exceptional compression ratios for light gases alongside an impressive foreline tolerance up to 18 mbar. This high tolerance allows the system to operate efficiently using significantly smaller backing\/primary dry or rotary vane pumps. The rotor assembly utilizes \u003cb data-path-to-node=\"5\" data-index-in-node=\"363\"\u003epermanently lubricated ceramic ball bearings\u003c\/b\u003e, eliminating the need for routine oil reservoirs or wick maintenance, guaranteeing 100% hydrocarbon-free operation with zero risk of backstreaming molecular contamination.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eFully Integrated Navigator Controller:\u003c\/b\u003e Factory-attached electronic drive unit provides immediate direct operation via RS-232\/RS-485 serial communication or remote analog I\/O without requiring separate rack controller space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003ePatented MacroTorr® Staging:\u003c\/b\u003e Maximizes throughput and dramatically extends backing pressure tolerance, allowing pairing with compact primary pumps (like the dry SH-100 or DS 102).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eMaintenance-Free Ceramic Bearings:\u003c\/b\u003e Permanently dry-lubricated ceramic bearings minimize friction, lower thermal profiles, and deliver an extended mean time to failure (MTTF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eTrue Omnidirectional Installation:\u003c\/b\u003e The contact-free internal tolerance and advanced dry balancing allow the pump assembly to be mounted and operated securely in any physical orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwit25Tsp8OVAxUAAAAAHQAAAAAQ2AM\"\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"10,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eVarian Vacuum Technologies (Now Agilent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eTurbo-V 301 Navigator System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003ePumping Speed (N₂)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e250 L\/s (ISO 100) \/ 280 L\/s (ISO 160 \/ CFF 8\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eCompression Ratio (N₂)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt; 2 \\times 10^8\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026gt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e2\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eMax Foreline Tolerance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e18 mbar (13.5 Torr)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eUltimate Base Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026lt; 2 \\times 10^{-10} \\text{ mbar}\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e2\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−10\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mbar\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"\u0026lt; 1.5 \\times 10^{-10} \\text{ Torr}\" data-index-in-node=\"34\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1.5\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−10\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Torr\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) \u003ci data-path-to-node=\"10,6,1,0\" data-index-in-node=\"70\"\u003ewith structural metal seals\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eRotational Operating Speed\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e56,000 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eRun-Up \/ Start Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026lt; 3\" data-index-in-node=\"0\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e3\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eIntegrated Controller Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e100–240 VAC (\u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"13\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e10%), Single Phase (50\/60 Hz) or 24 VDC variant options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eMaximum Operational Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e150 W (300 VA peak start profile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003e\u003cb data-path-to-node=\"10,11,0,0\" data-index-in-node=\"0\"\u003eSerial Communications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003eRS-232 \/ RS-485 serial data nodes via standard 9-pin D-Sub\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003e\u003cb data-path-to-node=\"10,12,0,0\" data-index-in-node=\"0\"\u003eCooling Profile\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003eNatural convection standard (Forced air or cooling water loops recommended for high gas-loads)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003e\u003cb data-path-to-node=\"10,12,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003e~12 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Varian","offers":[{"title":"Default Title","offer_id":47629914996925,"sku":null,"price":6239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/VarianTV301Navigatorwithcontroller_1.jpg?v=1783719121"},{"product_id":"edwards-scu-750-turbomolecular-pump-control-unit","title":"Edwards SCU-750 Turbomolecular Pump Control Unit","description":"\u003cp data-path-to-node=\"12\"\u003eThe \u003cb data-path-to-node=\"12\" data-index-in-node=\"4\"\u003eEdwards SCU-750\u003c\/b\u003e (P\/N PT56Z0Z10) is a high-performance control unit engineered to power and manage magnetically levitated turbomolecular pumps (specifically select STP series models). Designed for demanding industrial, semiconductor, and research vacuum systems, the SCU-750 delivers precise motor driving, advanced magnetic bearing control, and comprehensive system diagnostics in a compact unit.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003eIt provides automatic tuning, rotational speed monitoring, and robust safety protection mechanisms against power interrupts, thermal overload, and unbalance, ensuring smooth, low-vibration high-vacuum operation.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"15\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003e5-Axis Active Magnetic Bearing Control:\u003c\/b\u003e Maintains stable levitation for clean, hydrocarbon-free ultra-high vacuum environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eAuto-Tuning \u0026amp; Diagnostics:\u003c\/b\u003e Offers automated motor drive optimization and real-time fault detection for system reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eComprehensive Safeguards:\u003c\/b\u003e Built-in protection against power failure, excessive vibration, overspeed, and thermal overload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\"\u003eFlexible I\/O Integration:\u003c\/b\u003e Features remote parallel I\/O and RS-232\/RS-485 serial communication for integration into process control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003e\u003cb data-path-to-node=\"16,4,0\" data-index-in-node=\"0\"\u003eCompact Rack-Mount Design:\u003c\/b\u003e Standard enclosure size designed for cleanroom and rack-mount vacuum architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"18\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahcKEwjG04Dci-SVAxUAAAAAHQAAAAAQPQ\"\u003e\n\u003ctable data-path-to-node=\"19\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"19,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"19,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,0,0\"\u003e\u003cb data-path-to-node=\"19,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,1,0\"\u003eSCU-750\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,0,0\"\u003e\u003cb data-path-to-node=\"19,2,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,1,0\"\u003ePT56Z0Z10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,0,0\"\u003e\u003cb data-path-to-node=\"19,3,0,0\" data-index-in-node=\"0\"\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,1,0\"\u003e100–120 V \/ 200–240 V AC (\u003cspan class=\"math-inline\" data-math=\"\\pm10\\%\" data-index-in-node=\"26\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,0,0\"\u003e\u003cb data-path-to-node=\"19,4,0,0\" data-index-in-node=\"0\"\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,1,0\"\u003e50 \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,0,0\"\u003e\u003cb data-path-to-node=\"19,5,0,0\" data-index-in-node=\"0\"\u003ePower Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,1,0\"\u003e850 – 1200 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,6,0,0\"\u003e\u003cb data-path-to-node=\"19,6,0,0\" data-index-in-node=\"0\"\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,6,1,0\"\u003eSTP-603, STP-1003, STP-H301, STP-H451, STP-H803, STP-H1303, STP-A803, STP-A1303, STP-A1603\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,7,0,0\"\u003e\u003cb data-path-to-node=\"19,7,0,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,7,1,0\"\u003e0°C to 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,8,0,0\"\u003e\u003cb data-path-to-node=\"19,8,0,0\" data-index-in-node=\"0\"\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,8,1,0\"\u003eAir-cooled \/ Internal Fan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,9,0,0\"\u003e\u003cb data-path-to-node=\"19,9,0,0\" data-index-in-node=\"0\"\u003eInterface Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,9,1,0\"\u003eRemote I\/O (Parallel), Serial Comms (RS-232\/RS-485), Pump Cable Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,10,0,0\"\u003e\u003cb data-path-to-node=\"19,10,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,10,1,0\"\u003e~19 lbs (~8.6 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-path-to-node=\"21\"\u003e\u003c\/h2\u003e\n\u003ch2 data-path-to-node=\"21\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-path-to-node=\"22\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003eSemiconductor manufacturing and thin-film deposition tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003eSurface analysis instruments (XPS, SIMS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003eHigh-energy physics research and particle accelerators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,3,0\"\u003eIndustrial leak detection and analytical vacuum equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47696813523133,"sku":null,"price":6799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-750_1.jpg?v=1784648224"},{"product_id":"shimadzu-ei-d203m-turbomolecular-pump-controller","title":"Shimadzu EI-D203M Turbomolecular Pump Controller","description":"\u003cp data-path-to-node=\"7\" id=\"p-rc_a78d6038553bfdb4-65\"\u003e\u003cspan class=\"citation-132\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-132\"\u003eShimadzu EI-D203M\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-132\"\u003e is a dedicated digital turbomolecular pump controller designed to drive magnetically levitated turbomolecular pumps in the \u003c\/span\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"145\"\u003e\u003cspan class=\"citation-132\"\u003eShimadzu TMP-203M\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-132 citation-end-132\"\u003e series (such as the TMP-203M-G1).\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp data-path-to-node=\"8\" id=\"p-rc_a78d6038553bfdb4-66\"\u003e\u003cspan class=\"citation-131 citation-end-131\"\u003eEngineered for precision vacuum management, the EI-D203M controls magnetic levitation, rotor acceleration, rotational speed regulation, and real-time diagnostic reporting.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c\/sup\u003e\u003c\/span\u003e It provides power management and system protection for high-vacuum and ultra-high-vacuum (UHV) applications, making it essential for semiconductor equipment, mass spectrometers, and analytical systems.\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003e5-Axis Magnetic Levitation Control:\u003c\/b\u003e Manages the active magnetic bearing system for vibration-free, hydrocarbon-free vacuum performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eSystem Diagnostics \u0026amp; Monitoring:\u003c\/b\u003e Real-time speed output, temperature supervision, and fault monitoring for continuous operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eCompact Rack-Mount Design:\u003c\/b\u003e Standard industrial footprint designed for smooth integration into semiconductor tool racks or analytical instrument benches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eRemote \u0026amp; Local Interfaces:\u003c\/b\u003e Offers serial communication and I\/O logic for system integration and automated control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwiO3snwyeaVAxUAAAAAHQAAAAAQ6gE\"\u003e\n\u003ctable data-path-to-node=\"14\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"14,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"14,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,0,0\"\u003e\u003cb data-path-to-node=\"14,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,1,0\"\u003eShimadzu Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,0,0\"\u003e\u003cb data-path-to-node=\"14,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,1,0\"\u003eEI-D203M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,3,0,0\"\u003e\u003cb data-path-to-node=\"14,3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,3,1,0\"\u003eTurbomolecular Vacuum Pump Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,4,0,0\"\u003e\u003cb data-path-to-node=\"14,4,0,0\" data-index-in-node=\"0\"\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,4,1,0\"\u003eShimadzu TMP-203M \/ TMP-203M-G1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,5,0,0\"\u003e\u003cb data-path-to-node=\"14,5,0,0\" data-index-in-node=\"0\"\u003eBearing System Drive\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,5,1,0\"\u003e5-Axis Active Magnetic Levitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,6,0,0\"\u003e\u003cb data-path-to-node=\"14,6,0,0\" data-index-in-node=\"0\"\u003eCooling Requirements\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,6,1,0\"\u003eForced Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,7,0,0\"\u003e\u003cb data-path-to-node=\"14,7,0,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,7,1,0\"\u003eStandard 19\" Rack-Mountable Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\" id=\"p-rc_a78d6038553bfdb4-67\"\u003e\u003cspan class=\"citation-130 citation-end-130\"\u003eSemiconductor Manufacturing Equipment\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eGas Chromatography–Mass Spectrometry (GC-MS) \u0026amp; Analytical Instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eThin-Film Deposition \u0026amp; Surface Analysis Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eHigh-Vacuum Research Laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Shimadzu","offers":[{"title":"Default Title","offer_id":47705907298493,"sku":null,"price":3195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/ShimadzuEI-D203M_1.jpg?v=1784747023"},{"product_id":"leybold-turbotronik-nt-341m-i-electronic-frequency-converter-magnetic-bearing-controller","title":"Leybold TURBOTRONIK NT 341M\/I Electronic Frequency Converter \u0026 Magnetic Bearing Controller","description":"\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"4\"\u003eLeybold TURBOTRONIK NT 341M\/I\u003c\/b\u003e is an industrial-grade electronic frequency converter and active magnetic bearing controller designed to drive magnetically levitated Leybold TURBOVAC series turbomolecular pumps (such as the MAG 340, MAG 341, and MAG 400\/410 series).\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\" id=\"p-rc_26d62d70c6dfb4b6-137\"\u003e\u003cspan class=\"citation-273 citation-end-273\"\u003eEngineered specifically for high-reliability semiconductor process equipment—including Applied Materials (AMAT) processing platforms—the NT 341M\/I converts single-phase AC input into regulated DC power and high-frequency drive currents.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e It provides complete closed-loop management of the brushless DC motor and active 5-axis magnetic bearings, ensuring active rotor stabilization, low vibration, and real-time monitoring of pump operating parameters.\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eKey Features \u0026amp; Capabilities\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eIntegrated Dual Functionality:\u003c\/b\u003e Combines motor frequency drive and active 5-axis magnetic bearing control into a single rack-mount unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eSemiconductor Tool Ready (AMAT Compatible):\u003c\/b\u003e Specifically configured for integration with Applied Materials wafer-processing tools and OEM vacuum control interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eReal-Time Status Display:\u003c\/b\u003e Front-panel LED display arrays report rotor speed, motor load current, bearing magnetic levitation status, and system fault diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eComprehensive Sensor Feedback:\u003c\/b\u003e Continuously checks bearing currents and temperature parameters to protect against unbalance or thermal overload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\" id=\"p-rc_26d62d70c6dfb4b6-138\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eRemote \u0026amp; Local Automation Interface:\u003c\/b\u003e \u003cspan class=\"citation-272 citation-end-272\"\u003eFeatures terminal strips, remote logic I\/O, and serial communication (RS-232 \/ RS-485 interfaces) for remote tool integration.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwjmv_jYhPOVAxUAAAAAHQAAAAAQzQI\"\u003e\n\u003ctable data-path-to-node=\"15\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"15,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"15,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,1,0,0\"\u003e\u003cb data-path-to-node=\"15,1,0,0\" data-index-in-node=\"0\"\u003eModel Designation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,1,1,0\"\u003e\u003cb data-path-to-node=\"15,1,1,0\" data-index-in-node=\"0\"\u003eTURBOTRONIK NT 341M\/I\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,2,0,0\"\u003e\u003cb data-path-to-node=\"15,2,0,0\" data-index-in-node=\"0\"\u003eInput Voltage Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,2,1,0\"\u003e208 VAC (Single-Phase), 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,3,0,0\"\u003e\u003cb data-path-to-node=\"15,3,0,0\" data-index-in-node=\"0\"\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,3,1,0\"\u003eLeybold TURBOVAC MAG 340 M\/MC, MAG 341 MCT, MAG 400 MC, MAG 410 MCT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,4,0,0\"\u003e\u003cb data-path-to-node=\"15,4,0,0\" data-index-in-node=\"0\"\u003eMotor Drive Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,4,1,0\"\u003eFrequency-controlled 3-phase output for brushless DC motors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,5,0,0\"\u003e\u003cb data-path-to-node=\"15,5,0,0\" data-index-in-node=\"0\"\u003eBearing Control\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,5,1,0\"\u003eActive 5-Axis Magnetic Bearing Power Electronics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,6,0,0\"\u003e\u003cb data-path-to-node=\"15,6,0,0\" data-index-in-node=\"0\"\u003eCommunication \/ Control\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,6,1,0\"\u003eRS-232 \/ RS-485 interface \u0026amp; multi-pin terminal logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,7,0,0\"\u003e\u003cb data-path-to-node=\"15,7,0,0\" data-index-in-node=\"0\"\u003eForm Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,7,1,0\"\u003e19\" Rack-mountable enclosure (~17.5 kg \/ ~38.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,8,0,0\"\u003e\u003cb data-path-to-node=\"15,8,0,0\" data-index-in-node=\"0\"\u003eProtection \u0026amp; Fusing\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"15,8,1,0\"\u003eMulti-fuse circuit protection for logic, bearing, and line power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"17\"\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"17\"\u003eAuxiliary Connections \u0026amp; Support Functions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,0,0\"\u003e\u003cb data-path-to-node=\"18,0,0\" data-index-in-node=\"0\"\u003eForevacuum Pump Relay:\u003c\/b\u003e Integrated control contacts for automated interlock with primary backing pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,1,0\" id=\"p-rc_26d62d70c6dfb4b6-139\"\u003e\u003cb data-path-to-node=\"18,1,0\" data-index-in-node=\"0\"\u003eCooling \u0026amp; Venting Control:\u003c\/b\u003e \u003cspan class=\"citation-271 citation-end-271\"\u003eDedicated connection terminals for automated venting valves and external water\/air cooling fans.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,2,0\" id=\"p-rc_26d62d70c6dfb4b6-140\"\u003e\u003cb data-path-to-node=\"18,2,0\" data-index-in-node=\"0\"\u003eHeating Element Interlock:\u003c\/b\u003e \u003cspan class=\"citation-270 citation-end-270\"\u003eSolenoid and relay controls for chamber\/flange heater jackets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leybold","offers":[{"title":"Default Title","offer_id":47732979105981,"sku":null,"price":3899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/LeyboldTurbotronikNT341M_1.jpg?v=1785165010"},{"product_id":"leybold-mag-340m-and-controller-bundle","title":"Leybold TURBOVAC MAG 340 M Turbomolecular Vacuum System with TURBOTRONIK NT 341M\/I Controller Bundle","description":"\u003cp data-path-to-node=\"8\"\u003eThis complete high-vacuum bundle features the \u003cb data-index-in-node=\"46\" data-path-to-node=\"8\"\u003eLeybold TURBOVAC MAG 340 M\u003c\/b\u003e (Part Number 85583) 5-axis magnetically levitated turbomolecular pump paired directly with its matching \u003cb data-index-in-node=\"177\" data-path-to-node=\"8\"\u003eTURBOTRONIK NT 341M\/I\u003c\/b\u003e electronic frequency converter and active bearing controller.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eEngineered for clean, oil-free ultra-high vacuum (UHV) environments, this system eliminates all mechanical contact, wear, and oil lubrication from the pumping chamber. The active 5-axis magnetic suspension provides smooth, low-vibration rotor levitation, making this bundle ideal for sensitive analytical instrumentation, mass spectrometry, semiconductor research, and electron microscopy.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe included \u003cb data-index-in-node=\"13\" data-path-to-node=\"10\"\u003eTURBOTRONIK NT 341M\/I\u003c\/b\u003e rack-mount controller manages both the brushless DC motor drive and real-time active magnetic rotor stabilization. It features front-panel diagnostic displays, comprehensive fault protection, and remote tool control interfaces commonly deployed in semiconductor processing platforms and R\u0026amp;D installations.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eKey Features \u0026amp; System Benefits\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eTurnkey Mag-Lev Setup:\u003c\/b\u003e Includes both the 5-axis active magnetic levitation pump and its dedicated NT 341M\/I power drive controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003e100% Oil-Free Vacuum Generation:\u003c\/b\u003e Contactless magnetic levitation guarantees zero oil backstreaming, delivering clean vacuum for sensitive process chambers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eLow-Vibration \u0026amp; High Reliability:\u003c\/b\u003e Frictionless rotor suspension dramatically reduces operating vibration and extends service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eVersatile Orientation:\u003c\/b\u003e Contactless bearing design allows the pump body to be mounted in any position without oil-level restrictions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,4,0\"\u003eIntegrated Diagnostics \u0026amp; Safety:\u003c\/b\u003e The NT 341M\/I controller provides real-time speed, load current, and bearing levitation status, backed by mechanical emergency touch-down bearings inside the pump for safe power-loss deceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eSystem Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv data-ved=\"0CAAQ3ecQahgKEwjUleagpvOVAxUAAAAAHQAAAAAQiQE\" data-hveid=\"0\" class=\"table-content md-content\"\u003e\n\u003ctable data-path-to-node=\"16\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"16,0,0,0\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan data-path-to-node=\"16,0,1,0\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,1,0,0\"\u003ePump Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,1,1,0\"\u003e85583\u003c\/b\u003e (MAG 340 M)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,2,0,0\"\u003eController Model\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,2,1,0\"\u003eTURBOTRONIK NT 341M\/I\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,3,0,0\"\u003eInlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,1,0\"\u003eDN 100 ISO-K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,4,0,0\"\u003eExhaust \/ Fore-line Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,1,0\"\u003eDN 25 ISO-KF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,5,0,0\"\u003ePumping Speed (\u003cspan data-index-in-node=\"15\" data-math=\"N_2\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,1,0\"\u003e340 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,6,0,0\"\u003ePumping Speed (\u003cspan data-index-in-node=\"15\" data-math=\"He\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eHe\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,1,0\"\u003e310 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,7,0,0\"\u003ePumping Speed (\u003cspan data-index-in-node=\"15\" data-math=\"H_2\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eH\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,1,0\"\u003e220 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,8,0,0\"\u003eUltimate Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,8,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"\u0026lt; 1 \\times 10^{-9}\\text{ mbar}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−9\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mbar\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan data-index-in-node=\"32\" data-math=\"\u0026lt; 7.5 \\times 10^{-10}\\text{ Torr}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026lt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e7.5\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e−10\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e Torr\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,9,0,0\"\u003eCompression Ratio (\u003cspan data-index-in-node=\"19\" data-math=\"N_2\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,9,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"\u0026gt; 1 \\times 10^{9}\" class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan aria-hidden=\"true\" class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e\u0026gt;\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mbin\"\u003e×\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e9\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,10,0,0\"\u003eBearing Technology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,10,1,0\"\u003eActive 5-Axis Magnetic Levitation (Mag-Lev)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,11,0,0\"\u003eController Input Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,11,1,0\"\u003e208 VAC (Single-Phase), 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,12,0,0\"\u003eForm Factor \/ Mount\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,12,1,0\"\u003e19\" Rack-Mount Controller; ~16.0 kg pump \/ ~17.5 kg controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eCommon Applications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003eElectron Microscopy (SEM \/ TEM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003eMass Spectrometry \u0026amp; Analytical Research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003eSemiconductor Processing \u0026amp; Thin-Film Deposition Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003eSurface Science \u0026amp; Ultra-High Vacuum (UHV) Research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,4,0\"\u003eParticle Accelerators \u0026amp; Synchrotron Beamlines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"21\"\u003eWhat's Included in standard Package\u003c\/h3\u003e\n\u003cul data-path-to-node=\"22\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003eLeybold MAG 340 M Turbomolecular Pump (P\/N 85583)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003eLeybold TURBOTRONIK NT 341M\/I Drive\/Bearing Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003eComplete High-Flex Interconnect Cable Harness (Drive \u0026amp; Bearing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,3,0\"\u003ePower Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leybold","offers":[{"title":"Default Title","offer_id":47733138260157,"sku":null,"price":10398.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/LeyboldTurbovac340M_1.jpg?v=1785163404"},{"product_id":"seiko-seiki-scu-a803c-turbomolecular-vacuum-pump-controller","title":"Seiko Seiki SCU-A803C Turbomolecular Vacuum Pump Controller","description":"\u003cp id=\"p-rc_ddef92ea9704ea01-67\"\u003e\u003cspan class=\"citation-126\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-126\"\u003eSeiko Seiki SCU-A803C\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-126\"\u003e is a high-performance control unit engineered specifically for driving magnetically levitated (mag-lev) turbomolecular vacuum pumps in the \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-126\"\u003eSTP-A803C \/ STP-A803CV\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-125 citation-end-125\"\u003eDesigned for clean, hydrocarbon-free high-vacuum environments, this controller manages automatic tuning, real-time magnetic bearing levitation, and precise motor power delivery.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_ddef92ea9704ea01-68\"\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003eFeaturing extensive self-diagnostic functions, battery-free operation, and comprehensive status output ports, the SCU-A803C ensures maximum system safety and process uptime across semiconductor processing, thin-film deposition, and analytical instrumentation.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003eKey Features \u0026amp; Benefits\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Magnetic Bearing Management:\u003c\/b\u003e Continually monitors and adjusts magnetic levitation fields to dynamically balance rotor loads and suppress vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuto-Tuning \u0026amp; Self-Diagnostics:\u003c\/b\u003e Built-in routine checks for rapid deployment, fault detection, and simplified troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_ddef92ea9704ea01-69\"\u003e\u003cb\u003eDC Motor Drive Control:\u003c\/b\u003e \u003cspan class=\"citation-123 citation-end-123\"\u003eEnables fast ramp-up sequences (~7 minutes to full operational speed) and efficient power usage.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Footprint:\u003c\/b\u003e Half-rack industrial enclosure allows simple integration into OEM process tool cabinets or lab racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRemote \u0026amp; Automation Friendly:\u003c\/b\u003e Equipped with standard remote control I\/O interfaces for automated tool system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature \/ Metric\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeiko Seiki (BOC Edwards)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003eSCU-A803C\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePrimary Pump Pairing\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-A803C \/ STP-A803CV (800 L\/s Class)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e850\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e VA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e0.85\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e kVA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eFrequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Motor \/ Active 5-Axis Magnetic Bearing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBearing Backup System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical precision safety bearings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStatus Indicators\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAcceleration, Normal Operation, Brake, Fault\/Alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e∼\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e9.0\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e kg\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e19.8\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e lbs\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalf-Rack Mount \/ Desktop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-footer hide-on-print hide-from-message-actions\"\u003e\n\u003cbutton class=\"mdc-icon-button mat-mdc-icon-button mat-mdc-button-base mat-badge mat-unthemed mat-badge-overlap mat-badge-above mat-badge-after mat-badge-small mat-badge-hidden ng-star-inserted\"\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-icon-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003c\/button\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003eTypical Applications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_ddef92ea9704ea01-70\"\u003e\u003cspan class=\"citation-122 citation-end-122\"\u003eSemiconductor \u0026amp; Semiconductor Etch\/Implant Equipment\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_ddef92ea9704ea01-71\"\u003e\u003cspan class=\"citation-121 citation-end-121\"\u003eSurface Analysis \u0026amp; Mass Spectrometry Systems\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) \u0026amp; Solar Cell Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral Research \u0026amp; High-Energy Physics Vacuum Chambers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47928091705533,"sku":null,"price":4250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSTP-A803C_1.jpg?v=1785441436"},{"product_id":"edwards-seiko-seiki-scu-1400-turbomolecular-pump-controller","title":"Edwards \/ Seiko Seiki SCU-1400 Turbomolecular Pump Controller","description":"\u003cp id=\"p-rc_8269bd37504b6e73-90\"\u003e\u003cspan class=\"citation-157\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-157\"\u003eEdwards \/ Seiko Seiki SCU-1400\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-157 citation-end-157\"\u003e (Part Number: YT72Z0Z00) is a universal, high-capacity control unit designed for 5-axis magnetically levitated (mag-lev) turbomolecular vacuum pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Built to operate mid-to-large capacity STP-series pumps, the SCU-1400 handles dynamic magnetic bearing levitation, automatic rotor balancing, and motor speed control for hydrocarbon-free, ultra-high-vacuum (UHV) processes.\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_8269bd37504b6e73-91\"\u003e\u003cspan class=\"citation-156\"\u003eEquipped with an \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-156\"\u003eAuto Vibration Reduction (AVR)\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-156 citation-end-156\"\u003e system and comprehensive self-diagnostics, the SCU-1400 ensures exceptional thermal stability, reduced noise, and continuous operation in demanding semiconductor manufacturing, thin-film deposition, and surface science environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003eKey Features \u0026amp; Benefits\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUniversal Compatibility:\u003c\/b\u003e Drives a wide variety of 300 L\/s to 2200+ L\/s class mag-lev STP turbo pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Magnetic Bearing Management:\u003c\/b\u003e Uses 5-axis active magnetic levitation to eliminate mechanical bearing friction, extending pump life and reducing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuto Vibration Reduction (AVR) \u0026amp; Dynamic Balancing:\u003c\/b\u003e Minimizes mechanical noise and resonance transferred to the vacuum chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSelf-Diagnostics \u0026amp; Fault Isolation:\u003c\/b\u003e Monitors levitation status, temperature thresholds, rotor speed, and line power parameters to prevent pump damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFlexible I\/O Integration:\u003c\/b\u003e Includes remote parallel and serial communication ports for integration into automated tool controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature \/ Metric\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards Vacuum \/ Seiko Seiki\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003eSCU-1400\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~1500–2100 VA (Pump model dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLevitation Drive\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Requirement\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced air \/ internal fan cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132.5 mm x 209.7 mm x 380 mm (5.2\" x 8.25\" x 15.0\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~10.0 kg (~22 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePrimary Pump Pairing\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-301 \/ STP-451 \/ STP-A803C \/ STP-A1303 \/ STP-F2203\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cb\u003eTypical Applications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Etch, CVD, and PVD Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) and Solar Cell Production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMass Spectrometry \u0026amp; High-Energy Surface Analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral UHV Research Chambers and Space Simulation Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47928166088893,"sku":null,"price":5495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-1400_1.jpg?v=1785443025"},{"product_id":"edwards-seiko-seiki-scu-1600-lon-turbomolecular-pump-controller","title":"Edwards \/ Seiko Seiki SCU-1600 LON Turbomolecular Pump Controller","description":"\u003cp id=\"p-rc_e283bfded66b62c1-65\"\u003e\u003cspan class=\"citation-101\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-101\"\u003eEdwards \/ Seiko Seiki SCU-1600 LON \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-101\"\u003e(Part Number: YT76-Z2-Z20)\u003c\/span\u003e\u003cspan class=\"citation-101 citation-end-101\"\u003e is a fully digital, high-capacity turbomolecular pump control unit designed specifically for large-class, 5-axis magnetically levitated (mag-lev) STP turbo pumps (ranging from 2,000 L\/s to 4,500 L\/s).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_e283bfded66b62c1-66\"\u003eFeaturing built-in \u003cb\u003eLonWorks (LON) network communication\u003c\/b\u003e, this controller is tailored for high-density semiconductor tool integration, allowing automated multi-pump control, remote telemetry reporting, and streamlined tool networking. \u003cspan class=\"citation-100 citation-end-100\"\u003eIt includes advanced predictive maintenance algorithms, built-in Temperature Management System (TMS) support, and active vibration suppression to maximize process uptime.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003eKey Features \u0026amp; Benefits\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLonWorks (LON) Fieldbus Integration:\u003c\/b\u003e Enables seamless multi-node industrial network communication directly with host semiconductor process equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_e283bfded66b62c1-67\"\u003e\u003cb\u003eUniversal High-Capacity Support:\u003c\/b\u003e \u003cspan class=\"citation-99 citation-end-99\"\u003eEngineered to drive large-capacity mag-lev STP-series pumps (2,000 to 4,500 L\/s class).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Magnetic Levitation \u0026amp; Tuning:\u003c\/b\u003e Digitally regulates 5-axis active magnetic bearings to eliminate physical bearing friction and reduce rotor vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_e283bfded66b62c1-68\"\u003e\u003cb\u003eAdvanced Predictive Maintenance:\u003c\/b\u003e \u003cspan class=\"citation-98 citation-end-98\"\u003eTracks rotor imbalance, backup bearing wear limits, and thermal thresholds to warn operators before unexpected tool downtime occurs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIntegrated TMS Controller:\u003c\/b\u003e Built-in Temperature Management System driver prevents corrosive process gas condensation inside the pump chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature \/ Metric\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards Vacuum \/ Seiko Seiki\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003eSCU-1600 LON\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 1,500 VA (without TMS) \/ Max 2,100 VA (with TMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMotor Drive System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase DC Brushless Motor Driver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLevitation Drive\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital 5-Axis Active Magnetic Bearing System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLonWorks (LON), RS232 \/ RS485 Serial, Remote I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132.5 mm x 209.7 mm x 498.5 mm (5.2\" x 8.25\" x 19.6\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~11.0 kg to 12.0 kg (~24 to 26 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePrimary Pump Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-A2203 \/ A2503 \/ A2803 \/ A3003 \/ A3503 \/ XA4503 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cb\u003eTypical Applications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Density Semiconductor Etch, CVD, and Implantation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) and Solar Cell Production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtreme High-Vacuum (XHV) and Large-Chambers R\u0026amp;D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-Pump Automated Tool Interfaces via LonWorks Network\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47928800280765,"sku":null,"price":7398.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-1600LON_1.jpg?v=1785463182"},{"product_id":"edwards-scu-800-turbo-molecular-pump-control-unit","title":"Edwards SCU-800 Turbo Molecular Pump Control Unit","description":"\u003cp id=\"p-rc_71ff216d8443e74e-43\"\u003e\u003cspan class=\"citation-81\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-81\"\u003eEdwards SCU-800\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-81\"\u003e (Part Number: \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-81\"\u003eYT49-Z3-Z20\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-81 citation-end-81\"\u003e) is a fully digital, universal control unit designed for magnetically suspended turbomolecular pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-80 citation-end-80\"\u003eBuilt to support medium-capacity STP series turbo pumps, the SCU-800 incorporates Auto Vibration Reduction (AVR) and Auto Balancing System (ABS) technologies to minimize rotational vibration and deliver consistent, ultra-high vacuum performance.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-44\"\u003e\u003cspan class=\"citation-79 citation-end-79\"\u003eThis controller features standard serial communication interfaces (RS-232\/RS-485), advanced predictive maintenance alerts, and compliance with international semiconductor safety standards including CE, UL, and SEMI S2.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Digital Magnetic Bearing Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 200–240 VAC (±10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \/ 60 Hz (±2 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 850 VA (w\/o TMS) \/ Max 1200 VA (w\/ TMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMotor Drive System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMain Breaker Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eLeakage Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDisplay Panel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated LCD Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RS-232 \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132.5 mm × 209.7 mm × 380.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~8.5 kg (18.7–20 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSafety Compliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, SEMI S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-45\"\u003e\u003cspan class=\"citation-78 citation-end-78\"\u003eThe SCU-800 serves as a universal controller for middle-sized Edwards and Seiko Seiki Maglev turbomolecular pumps:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-46\"\u003e\u003cb\u003e\u003cspan class=\"citation-77 citation-end-77\"\u003eSTP-603 \/ STP-1003 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-47\"\u003e\u003cb\u003e\u003cspan class=\"citation-76 citation-end-76\"\u003eSTP-H301 \/ STP-H451 \/ STP-H803 \/ STP-H1303 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-48\"\u003e\u003cb\u003e\u003cspan class=\"citation-75 citation-end-75\"\u003eSTP-A803C \/ STP-A1303 \/ STP-A1603 Series\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-49\"\u003e\u003cb\u003eUniversal Compatibility:\u003c\/b\u003e \u003cspan class=\"citation-74 citation-end-74\"\u003eA single SCU-800 controller supports multiple middle-sized pump models, simplifying backup equipment inventories in multi-pump laboratory setups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Vibration Suppression:\u003c\/b\u003e Embedded Auto Vibration Reduction (AVR) dynamically balances the magnetic bearing suspension during acceleration and steady-state operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-50\"\u003e\u003cb\u003ePredictive Diagnostics:\u003c\/b\u003e \u003cspan class=\"citation-73 citation-end-73\"\u003eAdvanced pre-maintenance functions track run hours, rotor stability, and thermal loads to give notice prior to scheduled maintenance cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_71ff216d8443e74e-51\"\u003e\u003cb\u003eDual Serial Communication:\u003c\/b\u003e \u003cspan class=\"citation-72 citation-end-72\"\u003eIntegrated RS-232 and RS-485 ports enable concurrent connection to local PC interfaces and automated fab-wide monitoring systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47944473084093,"sku":null,"price":5495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-800_1.jpg?v=1785864810"},{"product_id":"edwards-seiko-seiki-scu-h803c1-turbo-molecular-pump-control-unit","title":"Edwards \/ Seiko Seiki SCU-H803C1 Turbo Molecular Pump Control Unit","description":"\u003cp\u003eThe \u003cb\u003eEdwards \/ Seiko Seiki SCU-H803C1\u003c\/b\u003e is a dedicated 5-axis digital magnetic bearing control unit engineered specifically to drive and monitor the \u003cb\u003eSTP-H803 \/ STP-H803C1\u003c\/b\u003e high-throughput turbomolecular pump series.\u003c\/p\u003e\n\u003cp\u003eUnlike general-purpose universal drivers, the SCU-H803C1 is factory-tuned to manage the high rotor dynamics, 5-axis active magnetic levitation, and thermal profiles associated with 800 L\/s corrosive-spec Maglev pumps. It features automated rotor balancing, dynamic vibration suppression, real-time diagnostic telemetry, and integrated safety interlocks for harsh semiconductor and analytical vacuum processes.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards \/ Seiko Seiki \u003cb\u003eSTP-H803 \/ STP-H803C \/ STP-H803C1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing (AMB) Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 200–240 VAC (1-Phase, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Frequency\/Drive\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Frequency 3-Phase Variable AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStatus \/ Display\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront Panel LED Indicator Array \u0026amp; LCD Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication \/ I\/O\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37-pin \/ 25-pin D-Sub Remote I\/O \u0026amp; RS-232 \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSafety Interlocks\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTMS (Temperature Management System) \u0026amp; Gas Purge Interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Requirement\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air \/ Internal Cooling Fan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19\" Rack Mountable (3U height profile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~9.5 kg (21 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTailored Rotor Dynamics:\u003c\/b\u003e Pre-tuned frequency profiles matched to the mass and inertia of the STP-H803 rotor assembly, ensuring fast acceleration cycles (\u0026lt;7 minutes) and smooth braking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIntegrated TMS \u0026amp; Purge Management:\u003c\/b\u003e Direct terminal connections to manage heating jackets and \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eN\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e purge gas pressure switches required for corrosive gas (\"C\" spec) operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Levitation Monitoring:\u003c\/b\u003e Continuously adjusts magnetic suspension current across 5 axes to compensate for transient shock or gas-load surges during high-throughput processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTool Interlock \u0026amp; System Integration:\u003c\/b\u003e Provides standard logic signals (START, STOP, NORMAL SPEED, FAILURE) for seamless handshake with main system PLC or chamber control software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47944506572989,"sku":null,"price":4495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-H803C1_1.jpg?v=1785865718"},{"product_id":"varian-turbo-v-550-ice-controller","title":"Varian Turbo-V 550 ICE Controller","description":"\u003cp id=\"p-rc_2605aa25bc05a3fc-89\"\u003e\u003cspan class=\"citation-179\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-179\"\u003eVarian (Agilent) Turbo-V 550 ICE Controller\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-179 citation-end-179\"\u003e is a solid-state, microprocessor-driven frequency converter designed to drive and monitor Varian Turbo-V 550 series turbomolecular vacuum pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-178 citation-end-178\"\u003eThe controller regulates current and voltage supplied to the pump during the ramp-up phase and adapts drive frequency during high gas-load processing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_2605aa25bc05a3fc-90\"\u003e\u003cspan class=\"citation-177 citation-end-177\"\u003eEquipped with an alphanumeric LCD front panel and membrane keypad, the controller provides real-time diagnostic reporting on rotational speed, power consumption, operating temperature, and pump cycle logging.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-176 citation-end-176\"\u003eSystem interlocks integrate with external cooling switches, pressure relays, and foreline valves to ensure automatic protection across UHV system setups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVarian \/ Agilent Turbo-V 550, TV-550HT, TV-551\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100, 120, 220, 240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Input Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Output Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54 VAC nominal (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 3-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Output Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e700 Hz (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e2%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Output Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e420 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDisplay Panel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlphanumeric LCD Display + Keyboard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAuxiliary Outlets\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJ6 (Fan): 120 VAC, 1A \/ J7 (Forepump\/Valve): 120 VAC, 1A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRemote Interlocks\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptoisolated P1 (Input) \u0026amp; J2 (Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSerial Communication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 \/ RS-422 \/ RS-485 (J14 board optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Half-Rack Profile (128.5 mm H x 213 mm W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~10.7 kg (24 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_2605aa25bc05a3fc-91\"\u003e\u003cb\u003eMicroprocessor-Controlled Drive:\u003c\/b\u003e \u003cspan class=\"citation-175 citation-end-175\"\u003eAutomatically ramps rotational speed while monitoring rotor temperature and power consumption to protect turbine bearings under load.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_2605aa25bc05a3fc-92\"\u003e\u003cb\u003eIntegrated Cycle Logging:\u003c\/b\u003e \u003cspan class=\"citation-174 citation-end-174\"\u003eOnboard EEPROM tracks total operating hours, current cycle elapsed time, and total vacuum start\/stop cycles for routine maintenance tracking.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuxiliary Power Control:\u003c\/b\u003e Dedicated J6\/J7 sockets power external cooling fans and foreline backing pump relays directly from the controller's logic states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComplete Fault Diagnostics:\u003c\/b\u003e Self-diagnostic error reporting identifies over-temperature, power imbalance, or improper foreline pressure conditions directly on the LCD panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Varian","offers":[{"title":"Default Title","offer_id":47944518140093,"sku":null,"price":2784.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/VarianTurboV-550_1.jpg?v=1785866271"},{"product_id":"pfeiffer-tc750-e74-electronic-drive-unit-controller","title":"Pfeiffer TC750-E74 Electronic Drive Unit \/ Controller","description":"\u003cp\u003eThe \u003cb\u003ePfeiffer TC750-E74\u003c\/b\u003e (Part Number: \u003cb\u003ePM C01 712\u003c\/b\u003e) is an electronic drive unit designed for direct attachment to mid-size and large Pfeiffer turbomolecular vacuum pumps. Operating as an integrated controller, the TC750-E74 regulates operational frequency, manages ramp-up profiles, monitors motor coil temperatures, and provides interlock protection.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003e\"E74\"\u003c\/b\u003e configuration variant includes integrated RS-485 serial communication, accessory connection outputs (for cooling fans or venting valves), and standard remote I\/O control for seamless tool integration.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 72 \/ 140 VDC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e5%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~750 W peak \/ 550 W continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 1,500 Hz variable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface \/ Communications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485 Serial \u0026amp; Remote Digital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAccessory Connectors\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15-Pin D-Sub \/ M12 Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eProtection Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 °C to 40 °C (41 °F to 104 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x D)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~60 mm x 120 mm x 160 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.7 kg (1.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp id=\"p-rc_559cc9533edd6e22-123\"\u003e\u003cspan class=\"citation-273 citation-end-273\"\u003eThe TC750-E74 (PM C01 712) drive unit mounts directly to or controls several popular Pfeiffer turbomolecular pump lines, including:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_559cc9533edd6e22-124\"\u003e\u003cb\u003eTMH \/ TMU Series:\u003c\/b\u003e \u003cspan class=\"citation-272 citation-end-272\"\u003eTMH 261, TMH 521, TMH 521 YP, TMU 521P, TMH 1001P\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_559cc9533edd6e22-125\"\u003e\u003cb\u003eTPH \/ TPU Series:\u003c\/b\u003e \u003cspan class=\"citation-271 citation-end-271\"\u003eTPH 1201, TPH 2101, TPH 2301, TPU 1501\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHiPace Series:\u003c\/b\u003e Select HiPace 700 \/ 800 configurations utilizing 750W drive modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIntegrated Pump Control:\u003c\/b\u003e Mounts directly to the pump casing to save rack space and eliminate high-frequency drive cable noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSmart Thermal \u0026amp; Load Monitoring:\u003c\/b\u003e Continuously monitors drive current and pump stator temperatures, automatically adjusting frequency under heavy gas loads to prevent thermal trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eStandard RS-485 Networking:\u003c\/b\u003e Enables daisy-chained remote control and diagnostic monitoring via standard Pfeiffer ASCII protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuxiliary Control Ports:\u003c\/b\u003e Directly powers and controls automated venting valves, sealing gas valves, and air-cooling units based on pump status (e.g., speed reached, error states).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":47944624341181,"sku":null,"price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PfeifferTC750-E74_1.jpg?v=1785867938"},{"product_id":"pfeiffer-tcp-310-turbo-molecular-pump-controller","title":"Pfeiffer TCP 310 Turbo Molecular Pump Controller","description":"\u003cp id=\"p-rc_63400a569326dfcc-137\"\u003e\u003cspan class=\"citation-325\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-325\"\u003ePfeiffer TCP 310\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-325\"\u003e (Part Number: \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-325\"\u003ePM C01 522\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-325 citation-end-325\"\u003e) is a versatile, rack-mountable electronic drive unit and power supply designed to drive classical Pfeiffer TPH, TPU, and TMH series turbomolecular vacuum pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-324 citation-end-324\"\u003eDesigned with front-panel controls, status LEDs, and a standby operational mode, the TCP 310 regulates rotor speed and power delivery across a wide range of industrial and research vacuum setups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_63400a569326dfcc-138\"\u003eThe controller features universal AC input voltage, automatic line-voltage sensing without manual changeover switches, and internal line filtering to suppress electrical noise. \u003cspan class=\"citation-323\"\u003eThe integrated \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-323\"\u003eStandby Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-323 citation-end-323\"\u003e permits running compatible turbo pumps at 66% of rated rotational speed, reducing vibration, lowering operating noise, and extending bearing life during idle cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110–240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~320 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Output Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~40 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStandby Function\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperates pump at 66% rated speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel pushbuttons \u0026amp; Status LEDs (Power, Speed, Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRemote Interlocks\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminals for heating jackets, air cooling, \u0026amp; safety interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Form Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2 Rack (3U Profile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~3.3 kg (7.3 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp\u003eThe TCP 310 serves as a primary rack controller for several classic Pfeiffer \/ Balzers turbomolecular pumps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_63400a569326dfcc-139\"\u003e\u003cb\u003eTPH \/ TPU Series:\u003c\/b\u003e \u003cspan class=\"citation-322 citation-end-322\"\u003eTPH\/TPU 110, TPH\/TPU 170, TPH\/TPU 240, TPH\/TPU 270, TPH\/TPU 330, TPH\/TPU 510\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTMH \/ TMU Series:\u003c\/b\u003e Select early-generation TMH\/TMU models matching 40V drive requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_63400a569326dfcc-140\"\u003e\u003cb\u003eUniversal Voltage Input:\u003c\/b\u003e \u003cspan class=\"citation-321 citation-end-321\"\u003eAccepts 110V to 240V AC power automatically without requiring transformer rewiring or selector switch adjustments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eStandby Mode Speed Reduction:\u003c\/b\u003e Idle mode drops rotational speed to 66%, saving energy and reducing bearing wear when ultra-high vacuum pumping speed is temporarily unneeded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_63400a569326dfcc-141\"\u003e\u003cb\u003eIntegrated Line Suppression:\u003c\/b\u003e \u003cspan class=\"citation-320 citation-end-320\"\u003eBuilt-in mains filter protects sensitive laboratory equipment against line pulses and high-frequency electrical feedback.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAccessory Switching:\u003c\/b\u003e Onboard relay terminals manage automatic power delivery to air-cooling fans, heating jackets, and foreline isolation valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":47944702722237,"sku":null,"price":1699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PfeifferTCP310_1.jpg?v=1785869276"},{"product_id":"pfeiffer-tcp-380-turbo-molecular-pump-controller","title":"Pfeiffer TCP 380 Turbo Molecular Pump Controller","description":"\u003cp id=\"p-rc_be539671612338ae-159\"\u003e\u003cspan class=\"citation-391\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-391\"\u003ePfeiffer TCP 380\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-391\"\u003e (Part Number: \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-391\"\u003ePM C01 680\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-391 citation-end-391\"\u003e) is a microprocessor-controlled electronic drive unit and power supply engineered to operate classical Pfeiffer \/ Balzers TPH, TPU, and TMH series turbomolecular vacuum pumps.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-390 citation-end-390\"\u003eFeaturing automated parameter recognition, the TCP 380 utilizes internal programming resistances to automatically identify the connected turbo pump model and set the appropriate operational thresholds for rated and maximum rotational speeds.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"source-title\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_be539671612338ae-160\"\u003e\u003cspan class=\"citation-389 citation-end-389\"\u003eThe front panel provides direct manual controls and real-time LED diagnostics for tracking motor temperature, housing temperature, oil flow, pump speed, and drive current.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-388\"\u003eIt also features an integrated \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-388\"\u003eStandby Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-388 citation-end-388\"\u003e, which lowers the turbopump speed to 66% of its rated RPM to reduce bearing wear, lower operating noise, and conserve energy during system idle periods.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~380 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Output Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~40 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStandby Function\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperates pump at 66% rated speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDiagnostics \u0026amp; Monitoring\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMotor current, rotor RPM, oil flow, motor \u0026amp; housing temp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel pushbuttons \u0026amp; LED status\/fault indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRemote \/ Accessory Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminals for heating jackets, air cooling fans, \u0026amp; safety interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19\" Rack Mountable (3U Profile \/ 1\/2-Rack width)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~9.1 kg (20 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp\u003eThe TCP 380 serves as a primary drive unit for a broad range of classic Pfeiffer \/ Balzers turbomolecular pumps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_be539671612338ae-161\"\u003e\u003cb\u003eTPH \/ TPU Series:\u003c\/b\u003e \u003cspan class=\"citation-387 citation-end-387\"\u003eTPH\/TPU 110, TPH\/TPU 140, TPH\/TPU 170, TPH\/TPU 180H, TPH\/TPU 190, TPH\/TPU 240, TPH\/TPU 270, TPH\/TPU 330, TPH\/TPU 450H, TPH\/TPU 510, TPH\/TPU 520, TPH\/TPU 520M, TPH\/TPU 1500\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_be539671612338ae-162\"\u003e\u003cb\u003eTMH \/ TMU Series:\u003c\/b\u003e \u003cspan class=\"citation-386 citation-end-386\"\u003eTMH\/TMU 520, TMH\/TMU 260\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAutomatic Pump Recognition:\u003c\/b\u003e Microprocessor automatically detects the pump model via coding resistors in the interconnect cable, preventing overspeed errors and improper power delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComprehensive Telemetry:\u003c\/b\u003e Continuously monitors oil flow and thermal conditions to protect both the drive electronics and the pump rotor from over-temperature damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_be539671612338ae-163\"\u003e\u003cb\u003eStandby Mode Operation:\u003c\/b\u003e \u003cspan class=\"citation-385 citation-end-385\"\u003eReduces rotational speed to 66% during idle times, significantly extending bearing service life and lowering lab noise levels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUniversal Mains Supply:\u003c\/b\u003e Auto-sensing 100–240 VAC input simplifies installation across international power standards without manual transformer rewiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pfeiffer","offers":[{"title":"Default Title","offer_id":47944811643069,"sku":null,"price":2295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/PfeifferTCP380_1.jpg?v=1785872453"},{"product_id":"edwards-seiko-seiki-scu-301-turbo-molecular-pump-controller","title":"Edwards \/ Seiko Seiki SCU-301 Turbo Molecular Pump Controller","description":"\u003cp id=\"p-rc_4ddacb21cf5fd409-179\"\u003eThe \u003cb\u003eEdwards \/ Seiko Seiki SCU-301\u003c\/b\u003e is a 5-axis active magnetic bearing (AMB) control unit engineered to drive and monitor middle-capacity STP-301 and STP-451 series turbomolecular vacuum pumps. \u003cspan class=\"citation-417 citation-end-417\"\u003eOperating as a half-rack, solid-state frequency converter, the SCU-301 regulates magnetic levitation current to provide friction-free, oil-free rotor suspension with minimal operational vibration.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003cp id=\"p-rc_4ddacb21cf5fd409-180\"\u003e\u003cspan class=\"citation-416 citation-end-416\"\u003eDesigned with automatic vibration reduction (AVR), self-diagnostic logic, and emergency battery-free power levitation, the SCU-301 ensures complete rotor stabilization across acceleration, steady-state high-vacuum operation, and automatic dynamic braking cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container luminous-sources hide-from-message-actions ng-star-inserted\"\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump Series\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards \/ Seiko Seiki STP-301, STP-301C, STP-451, STP-451C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing (AMB) Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~550 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRated Output Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable AC output driving rotor to ~48,000 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eStatus \/ Display\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel status indicators (ACCEL, NORMAL, BRAKE, ALARM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRemote Interlocks \u0026amp; I\/O\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37-pin Remote I\/O terminal connector \u0026amp; Parallel Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalf-Rack Mountable Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~6.8 kg (15 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp\u003eThe SCU-301 serves as a dedicated drive unit for 300 L\/s and 450 L\/s maglev turbomolecular pumps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSTP-301 Series:\u003c\/b\u003e STP-301 (Standard), STP-301C (Corrosive-Spec)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSTP-451 Series:\u003c\/b\u003e STP-451 (Standard), STP-451C (Corrosive-Spec)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Magnetic Suspension:\u003c\/b\u003e Keeps the turbopump rotor levitated across 5 axes without mechanical contact, eliminating oil backstreaming risks and mechanical bearing wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuto Tuning \u0026amp; Self-Diagnostics:\u003c\/b\u003e Integrated control circuitry continuously monitors rotor position and automatically diagnoses sensor or motor faults to trigger safe system shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBattery-Free Emergency Protection:\u003c\/b\u003e Utilizes back-EMF energy generated by the spinning rotor to maintain magnetic levitation during unexpected mains power loss, safely decelerating the rotor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Half-Rack Footprint:\u003c\/b\u003e Standard 3U half-rack width allows easy integration into instrument cabinets or process tool chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47945110454461,"sku":null,"price":4195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-301_1.jpg?v=1785875049"},{"product_id":"edwards-seiko-seiki-scu-21d-turbo-molecular-pump-controller","title":"Edwards \/ Seiko Seiki SCU-21D Turbo Molecular Pump Controller","description":"\u003cp\u003eThe \u003cb\u003eEdwards \/ Seiko Seiki SCU-21D\u003c\/b\u003e is a universal electronic control unit engineered to drive and monitor 5-axis magnetically levitated (Maglev) turbomolecular pumps, particularly the STP-301 and related series. Originally developed by Seiko Seiki (whose turbopump division was later acquired by Edwards), this controller provides friction-free rotor suspension, eliminating the need for internal bearing lubrication and preventing hydrocarbon contamination in ultra-high vacuum environments.\u003c\/p\u003e\n\u003cp\u003eThis controller incorporates advanced Auto Vibration Reduction (AVR) and an Auto Balancing System (ABS). These technologies dynamically adjust magnetic suspension currents in real-time to counteract rotor imbalance, ensuring exceptionally smooth, low-vibration operation across all rotational speeds.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing (AMB) Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 200–240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~550 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable AC drive output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eVibration Suppression\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAuto Vibration Reduction (AVR) \u0026amp; Auto Balancing System (ABS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication \/ I\/O\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Remote I\/O terminal connector \u0026amp; Serial Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions (H x W x L)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132.5 mm x 209.7 mm x 400.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~8.6 kg (19 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp\u003eThe SCU-21D is designed to pair with Edwards \/ Seiko Seiki medium-capacity maglev pumps, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSTP-301 Series:\u003c\/b\u003e STP-301 (Standard), STP-301C (Corrosive-Spec), STP-301CVB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTotal Oil-Free Operation:\u003c\/b\u003e 5-axis active magnetic levitation completely removes mechanical bearing friction and wear, translating to near-zero maintenance cycles and zero oil backstreaming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuto Vibration Reduction (AVR):\u003c\/b\u003e Internal logic actively compensates for minor shifts in the pump's center of mass, delivering the ultra-low vibration profiles required for electron microscopy and sensitive surface analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAuto Balancing System (ABS):\u003c\/b\u003e Stabilizes the rotor dynamically during both the critical run-up acceleration phase and high-gas-load processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBattery-Free Emergency Braking:\u003c\/b\u003e In the event of a facility power failure, the controller harvests back-EMF generated by the spinning rotor to keep the magnetic bearings powered while the pump safely decelerates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47945159606461,"sku":null,"price":4195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-21D_1.jpg?v=1785878422"},{"product_id":"leybold-nt-341-mct-turbomolecular-pump-controller","title":"Leybold NT 341 MCT Turbomolecular Pump Controller","description":"\u003cp\u003eThe \u003cb\u003eLeybold NT 341 MCT\u003c\/b\u003e (Part Number: \u003cb\u003e85734\u003c\/b\u003e) is a high-reliability electronic drive unit and power supply designed to drive and manage classic Leybold TURBOVAC series turbomolecular vacuum pumps equipped with ceramic ball bearings and active temperature management systems. Operating as a rack-mountable controller, the NT 341 MCT converts single-phase AC line power into variable-frequency drive current to maintain optimal rotor speeds up to 36,000 RPM.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003e\"MCT\"\u003c\/b\u003e designation indicates specialized integration features, including motor drive output, dynamic heating\/cooling regulation, and remote monitoring terminal connections. The controller incorporates active electronic protection against over-temperature, current overloads, and improper foreline pressure, making it ideal for laboratory UHV applications, mass spectrometry, and semiconductor processing.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 \/ 120 \/ 220 \/ 240 VAC (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003cspan class=\"mord\"\u003e10%\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e), 1-Phase (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMax Power Output\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~500 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Drive Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase Variable AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Frequency Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 600 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eFront Panel Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog status meters \/ Status LEDs (RPM, Power, Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRemote Interlocks \u0026amp; I\/O\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25-pin D-Sub Remote Control Terminal \u0026amp; Temperature Sensor Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eAuxiliary Output Control\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect terminals for Air Cooling Fans, Venting Solenoid Valves, \u0026amp; TMS Heaters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19\" Rack Mountable (3U Profile \/ Half-Rack Width)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 45 °C (32 °F to 113 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~7.2 kg (15.8 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompatible Turbo Pump Series\u003c\/h2\u003e\n\u003cp\u003eThe NT 341 MCT serves as a primary electronic controller for classic Leybold TURBOVAC turbomolecular pumps, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTURBOVAC 340 M \/ 340 MCT Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTURBOVAC 151 \/ 151C, 361 \/ 361C, 600 \/ 600C Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTURBOVAC 1000 \/ 1000C Series\u003c\/b\u003e (when configured within power output bounds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Lab Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIntegrated Temperature Management (MCT):\u003c\/b\u003e Controls external heating jackets and cooling fans directly to manage condensation of low-volatility process gases inside the turbopump housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSelectable Line Voltage:\u003c\/b\u003e Multi-tap transformer architecture accommodates major global AC voltage standards via standard fuse block jumpers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComprehensive Fault Diagnostics:\u003c\/b\u003e Front-panel indicators and remote interlock terminals provide immediate monitoring of motor temperature, rotor acceleration, and speed thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRobust Analog\/Digital Remote Control:\u003c\/b\u003e Enables automated tool interlock handshake (START, STOP, NORMAL SPEED REACHED, ERROR) with main PLC control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leybold","offers":[{"title":"Default Title","offer_id":47945216131261,"sku":null,"price":2295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/LeyboldNT341MCT_1.jpg?v=1785881487"},{"product_id":"alcatel-adixen-act-2300m-lon-turbomolecular-pump-controller","title":"Alcatel \/ Adixen ACT 2300M LON Turbomolecular Pump Controller","description":"\u003cp\u003eThe \u003cb\u003eAlcatel \/ Adixen ACT 2300M LON\u003c\/b\u003e is an advanced 5-axis active magnetic bearing turbomolecular pump controller designed specifically to operate the Alcatel \/ Adixen ATH 2300M series mag-lev vacuum pumps. Built with integrated \u003cb\u003eLON (Local Operating Network)\u003c\/b\u003e protocol communication, this controller provides real-time digital monitoring, automated rotational speed management, active magnetic levitation control, and system safety interlocks for semiconductor tools and ultra-high vacuum (UHV) research systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Capabilities\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActive Magnetic Bearing Control:\u003c\/b\u003e Manages 5-axis magnetic levitation feedback loops to maintain stable rotor positioning with near-zero vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLON Interface Protocol:\u003c\/b\u003e Integrated Local Operating Network interface allows seamless industrial fieldbus integration, remote telemetry, and tool automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComprehensive Safety Interlocks:\u003c\/b\u003e Built-in safeguards monitor rotor speed, bearing temperature, motor current, and power loss handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUniversal Voltage Support:\u003c\/b\u003e Configured for high-efficiency power delivery across standard lab and fab supply voltages (100–240 VAC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFront Panel Diagnostics:\u003c\/b\u003e Provides visual status indicators for operational readiness, speed reaching, fault conditions, and bearing levitation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlcatel \/ Adixen (Pfeiffer Vacuum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACT 2300M LON\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eController for ATH 2300M Mag-Lev Turbos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 \/ 200–240 VAC (1-Phase, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCommunication Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLONWorks (Local Operating Network) \/ RS-232\/485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBenchtop or Rack-Mountable Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~19 lbs (8.6 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Alcatel","offers":[{"title":"Default Title","offer_id":47947878367421,"sku":null,"price":4199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/AlcatelACT2300MLON_1.jpg?v=1785944605"},{"product_id":"mitsubishi-ft-3301w-t8-3085a-turbomolecular-pump-controller","title":"Mitsubishi FT-3301W-T8-3085A Turbomolecular Pump Controller","description":"\u003cp\u003eThe Mitsubishi Heavy Industries FT-3301W-T8-3085A Controller is a specialized 5-axis magnetic bearing drive unit engineered to power, control, and levitate Mitsubishi FT-3301W series high-capacity turbomolecular pumps. It provides real-time digital levitation control, automated frequency acceleration, and advanced thermal\/rotor status monitoring. Built for high-reliability semiconductor wafer manufacturing and large-scale industrial vacuum systems, the controller features robust protection against line fluctuations and process overload, ensuring continuous, vibration-free turbomolecular pump operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFT-3301W-T8-3085A Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMitsubishi FT-3301W Series Turbomolecular Pumps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing Drive \u0026amp; Motor Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 3-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput \/ Drive Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Frequency Inverter Drive Output (~3.3 kW Max Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 \/ RS-485 Serial, Remote I\/O Control, Status Relay Interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air \/ Internal Fan Cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMounting Format\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch Rack Mount \/ Benchtop Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 7.0\" H x 19.0\" W x 18.5\" D (178 mm x 483 mm x 470 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~48.5 lbs (22 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eTarget Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Wafer Processing Systems (Etch, CVD, PVD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) Vacuum Deposition Chambers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar \u0026amp; Photovoltaic Panel Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge Industrial High-Vacuum Research Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect OEM Tool Controller Replacement \u0026amp; Retrofitting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":47983841444029,"sku":null,"price":8499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/MitsubishiFT-3301W-T8-3085A_1.jpg?v=1786574391"},{"product_id":"osaka-tc1103-power-supply-and-controller","title":"Osaka TC1103 Power Supply and Controller","description":"\u003cp\u003eThe Osaka Vacuum TC1103 is a specialized power supply and controller interface designed to drive and manage Osaka magnetically levitated and high-performance turbomolecular pumps. It delivers precise frequency inverter power while continuously managing magnetic bearing stability and rotor levitation dynamics. Engineered for demanding semiconductor and research vacuum tools, the TC1103 includes automated interlock monitoring, thermal overload safeguards, and remote communication capabilities to ensure reliable continuous pump operation.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC1103 Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOsaka Vacuum, Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTurbomolecular Pump Controller \u0026amp; Levitation Power Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 200–240 VAC, 1-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutput Characteristics\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Frequency Inverter Output \/ Magnetic Bearing Drive Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air \/ Internal Fan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eEnclosure Format\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBenchtop \/ Standard 19\" Rack-Mount Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 5.25\" H x 19.0\" W x 16.5\" D (133 mm x 483 mm x 419 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~28.6 lbs (13 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Wafer Manufacturing Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUniversity \u0026amp; National UHV Research Laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThin-Film Deposition \u0026amp; Optical Coating Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMass Spectrometry \u0026amp; Surface Analysis Tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Osaka","offers":[{"title":"Default Title","offer_id":47994265174205,"sku":null,"price":3195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/OsakaTC1103_1.jpg?v=1786725982"},{"product_id":"shimadzu-ei-d303m-turbomolecular-pump-controller","title":"Shimadzu EI-D303M Turbomolecular Pump Controller","description":"\u003cp\u003eThe Shimadzu EI-D303M is an advanced electronic drive unit engineered for controlling Shimadzu magnetically levitated turbomolecular pumps (such as the EI-303M series). Operating completely oil-free through 5-axis active magnetic levitation, the controller manages motor rotation, rotor position sensing, and automatic braking sequences. Its robust protective logic guards against power loss, gas surge overloads, and thermal anomalies, making it a critical component for ultra-clean semiconductor processing and analytical instruments.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEI-D303M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShimadzu Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShimadzu EI-303M \/ Related Mag-Lev Turbomolecular Pumps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Magnetic Levitation \u0026amp; Motor Inverter Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 1-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232C \/ RS-485 Serial, Remote I\/O Interlock Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir Cooled (Internal Fan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 5.9\" H x 17.0\" W x 15.0\" D (150 mm x 432 mm x 381 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~33 lbs (15 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectron Microscopy \u0026amp; Analytical Instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Etch, CVD, and PVD Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) Vacuum Chambers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVacuum Metallurgy \u0026amp; Thin-Film Coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Shimadzu","offers":[{"title":"Default Title","offer_id":47994269302973,"sku":null,"price":4295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/ShimadzuEI-D303M_1.jpg?v=1786727572"},{"product_id":"edwards-scu-350ha-turbomolecular-pump-controller","title":"Edwards SCU-350HA Turbomolecular Pump Controller","description":"\u003cp\u003eThe Edwards SCU-350HA (Part Number: YT21-ZD-Z10) is a compact, high-efficiency digital controller specifically built to drive Edwards and Seiko Seiki magnetically levitated turbomolecular pumps. Featuring digital 5-axis magnetic bearing management, auto-tuning, and extensive real-time diagnostics, it provides high stability and low vibration operation. The SCU-350HA is equipped with versatile serial and parallel communication interfaces for seamless tool integration across automated semiconductor production lines.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYT21-ZD-Z10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCU-350HA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards Vacuum \/ Seiko Seiki\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pumps\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards STP-301 \/ STP-451 \/ STP-A350 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 VAC, 1-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Bearing Drive \u0026amp; Motor Frequency Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface Options\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232C \/ Parallel I\/O \/ Remote Relay Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 5.0\" H x 8.5\" W x 14.0\" D (128 mm x 216 mm x 355 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~17.6 lbs (8 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Wafer Processing Tools (Etch, CVD, Ion Implantation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Surface Coating \u0026amp; Optical Deposition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhotovoltaic \u0026amp; Solar Cell Vacuum Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUHV Physics Chambers \u0026amp; Accelerators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47994272678077,"sku":null,"price":5195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-350HA_1.jpg?v=1786727853"},{"product_id":"edwards-stp-ixa3305cp-turbomolecular-pump","title":"Edwards STP-iXA3305CP Turbomolecular Pump","description":"\u003cp\u003eThe Edwards STP-iXA3305CP is a next-generation, high-throughput magnetically levitated turbomolecular pump featuring a fully integrated controller (\"iXA\" series). Delivering 3,300 L\/s class pumping speed, it eliminates the need for a separate rack-mounted controller cabinet, significantly reducing tool footprint and cabling complexity. Engineered for severe chemical process duty (\"CP\" corrosive variant), it incorporates advanced rotor protection, purge gas management, and optimized thermal control to manage heavy process gas loads in aggressive semiconductor etch and CVD environments.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYT77-0Z-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-iXA3305CP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVG300 \/ ISO-300F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKF-40 (NW40)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePumping Speed (N2)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~3,300 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Integrated On-Pump Digital Controller (No External Control Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBearing System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Levitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater Cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOperating Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 3-Phase or 1-Phase Configurable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 21.3\" H x 16.5\" Outer Diameter (540 mm x 420 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~187 lbs (85 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Throughput Semiconductor Plasma Etch \u0026amp; CVD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) Vacuum Deposition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar Cell Layer Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarsh Corrosive Chemical Process Gas Handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47994281820349,"sku":null,"price":24985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSTP-iXA3305CP_1.jpg?v=1786728588"},{"product_id":"edwards-stp-ixa3306cv-turbomolecular-pump","title":"Edwards STP-iXA3306CV Turbomolecular Pump","description":"\u003cp\u003eThe Edwards STP-iXA3306CV is a ultra-high performance magnetically levitated turbomolecular pump with an integrated onboard controller, designed for high-capacity industrial vacuum processes. The \"CV\" variant provides specialized corrosion resistance and thermal management for heavy process throughput. Featuring a 5-axis magnetic bearing structure and optimized rotor hydraulics, the pump provides high pumping speeds for nitrogen, argon, and light gases without oil contamination or mechanical bearing wear.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYT82-20-090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-iXA3306CV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVG300 \/ ISO-300F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKF-40 (NW40)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePumping Speed (N2)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~3,300 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBearing System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Levitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated On-Pump Digital Drive Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater Cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eMounting Orientation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal \/ Vertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 21.5\" H x 16.5\" Outer Diameter (546 mm x 420 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~189 lbs (86 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Wafer Manufacturing (Etch, PVD, CVD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-Area Flat Panel \u0026amp; OLED Vacuum Deposition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Surface Coating \u0026amp; Metallurgy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Capacity Research Chamber Pumping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47994286735549,"sku":null,"price":23499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSTP-iXA3306CV_1.jpg?v=1786728912"},{"product_id":"edwards-stp-ixa4506bv5-turbomolecular-pump","title":"Edwards STP-iXA4506BV5 Turbomolecular Pump","description":"\u003cp\u003eThe Edwards STP-iXA4506BV5 is a ultra-high capacity, magnetically levitated turbomolecular pump featuring a fully integrated controller and power supply unit (\"iXA\" series). Achieving pumping speeds up to 4,300 L\/s, it eliminates external controller racks and interconnect cabling to dramatically save tool footprint. The \"BV5\" designation indicates an optimized high-throughput rotor configuration with built-in Temperature Management System (TMS) heaters and corrosion-resistant coatings, making it ideal for high-flow, process-heavy semiconductor etch, LCD, and solar thin-film applications.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYT78-65-090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTP-iXA4506BV5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVG350 \/ ISO-320F \/ VG400 Options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eOutlet Flange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKF-40 (NW40)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePumping Speed (N2)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,300 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eControl Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Integrated On-Pump Digital Drive \u0026amp; Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBearing System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Active Magnetic Levitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTemperature Management\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated TMS (Heater \/ Water Control Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater Cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 1-Phase \/ 3-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 22.0\" H x 18.0\" Outer Diameter (558 mm x 457 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~240 lbs (109 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Throughput Semiconductor Plasma Etch \u0026amp; Chemical Vapor Deposition (CVD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-Area Flat Panel Display (LCD\/OLED) Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar Cell \u0026amp; Photovoltaic PVD Deposition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Glass \u0026amp; Optical Coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":47994436616381,"sku":null,"price":28575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSTP-iXA4506BV5_1.jpg?v=1786734030"},{"product_id":"seiko-seiki-edwards-scu-h803c-turbomolecular-pump-controller","title":"Seiko Seiki \/ Edwards SCU-H803C Turbomolecular Pump Controller","description":"\u003cp\u003eThe Seiko Seiki \/ Edwards SCU-H803C is a high-performance digital controller engineered to drive and levitate the STP-H803C series magnetically levitated turbomolecular pumps. Built with a 5-axis active magnetic bearing suspension system, it manages motor frequency, rotor levitation, and thermal limits without physical contact. Equipped with parallel I\/O and serial communication capabilities, the controller ensures seamless integration into automated process tools while offering real-time diagnostic readouts and protective interlock safeguards.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCU-H803C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeiko Seiki \/ Edwards Vacuum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards \/ Seiko Seiki STP-H803C Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Magnetic Levitation \u0026amp; Motor Inverter Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 1-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface Options\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerial RS-232C, Remote Parallel I\/O, Status Relay Interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCooling Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air \/ Internal Fan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 5.9\" H x 17.0\" W x 15.5\" D (150 mm x 432 mm x 394 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~31 lbs (14 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Wafer Etching \u0026amp; Deposition Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVacuum Coating \u0026amp; Optical Thin-Film Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) Vacuum Platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM Controller Replacement \u0026amp; Retrofitting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":48103054770365,"sku":null,"price":4249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-H803C_1.jpg?v=1787005288"},{"product_id":"seiko-seiki-edwards-scu-h1303cv3-turbomolecular-pump-controller","title":"Seiko Seiki \/ Edwards SCU-H1303CV3 Turbomolecular Pump Controller","description":"\u003cp\u003eThe Seiko Seiki \/ Edwards SCU-H1303CV3 is an advanced, heavy-duty digital controller designed specifically for the STP-H1303CV3 series magnetically levitated turbomolecular pumps. The \"CV3\" specification designates support for corrosive chemical process variants equipped with Temperature Management Systems (TMS). The controller regulates 5-axis magnetic rotor suspension, motor speed, and integrated heating band power to prevent process gas condensation, ensuring maximum operational reliability in severe semiconductor fabrication environments.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content md-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCU-H1303CV3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeiko Seiki \/ Edwards Vacuum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCompatible Pump\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEdwards \/ Seiko Seiki STP-H1303CV3 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Axis Magnetic Bearing Suspension \u0026amp; TMS Temperature Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInput Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 VAC, 1-Phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTMS Control Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Heater Power Output \u0026amp; Thermal Sensor Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eInterface Options\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232C \/ RS-485, Remote Parallel I\/O, Emergency Interlocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 6.8\" H x 19.0\" W x 16.5\" D (173 mm x 483 mm x 419 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~37.5 lbs (17 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eTarget Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCorrosive Semiconductor Processing (Etch, CVD, PECVD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat Panel Display (FPD) Vacuum Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar \u0026amp; Photovoltaic Layer Deposition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect Replacement for Legacy Seiko Seiki Control Racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":48111047147709,"sku":null,"price":5295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/1016\/9021\/files\/EdwardsSCU-H1303CV3_1.jpg?v=1787009803"}],"url":"https:\/\/labvac.com\/collections\/controllers.oembed?page=4","provider":"Labvac","version":"1.0","type":"link"}